Brannan 10/350/0 | BS 718 M50 Density Hydrometer | 1.60 to 1.65 g/ml, 270 mm
Brannan 10/350/0 reads liquid density between 1.60 and 1.65 g/ml and belongs to the M50 series of BS 718:1991 hydrometers. The 1.60–1.65 g/ml scale of this 270 mm hydrometer is divided in 0.001 g/ml steps, and readings on the 10/350/0 are referenced to 20 °C. Made in the UK, each 10/350/0 arrives in a resealable plastic tube for protection and storage.
Key features
- Reads 1.60 to 1.65 g/ml directly (M50)
- Reads to 0.001 g/ml between 1.60 and 1.65 g/ml, accuracy 0.001 g/ml
- 270 mm M50 body, part 10/350/0
- Medium surface tension class for the M50 1.60–1.65 g/ml range
- 10/350/0 can be supplied with UKAS or traceable certification
If documented calibration is needed, the 10/350/0 can be ordered with a UKAS certificate, a traceable certificate to a recognised national standard, or a Statement of Conformity.
- Specifications
- Downloads
| Part Number | 10/350/0 |
| Brand | Brannan |
| Standard | BS 718:1991, M50 series |
| Range | 1.60 to 1.65 g/ml |
| Range Span | 0.050 g/ml |
| Divisions | 0.001 g/ml |
| Accuracy | 0.001 g/ml |
| Overall Length | 270 mm |
| Bulb Diameter | 20 to 24 mm |
| Approx. Weight | 42 g (incl. 14 g plastic tube) |
| Material | Soda glass, steel shot ballast, synthetic wax resin |
| Adjusted At | 20 °C |
| Surface Tension | Medium |
| Country of Manufacture | UK |
Related Products
Brannan 10/468/0 | BS 718 L50 SP Density Hydrometer | 1.00 to 1.05 g/ml, 335 mm, low surface tension
Brannan 10/468/0 | BS 718 L50 SP Density Hydrometer | 1.00 to 1.05 g/ml, 335 mm, low surface tension
Brannan 10/466/0 | BS 718 L50 SP Density Hydrometer | 0.90 to 0.95 g/ml, 335 mm, low surface tension
Brannan 10/466/0 | BS 718 L50 SP Density Hydrometer | 0.90 to 0.95 g/ml, 335 mm, low surface tension
Brannan 10/467/0 | BS 718 L50 SP Density Hydrometer | 0.95 to 1.00 g/ml, 335 mm, low surface tension
Brannan 10/467/0 | BS 718 L50 SP Density Hydrometer | 0.95 to 1.00 g/ml, 335 mm, low surface tension
Brannan 10/465/0 | BS 718 L50 SP Density Hydrometer | 0.85 to 0.90 g/ml, 335 mm, low surface tension
Brannan 10/465/0 | BS 718 L50 SP Density Hydrometer | 0.85 to 0.90 g/ml, 335 mm, low surface tension
Brannan 10/461/0 | BS 718 L50 SP Density Hydrometer | 0.65 to 0.70 g/ml, 335 mm, low surface tension
Brannan 10/461/0 | BS 718 L50 SP Density Hydrometer | 0.65 to 0.70 g/ml, 335 mm, low surface tension
Brannan 10/462/0 | BS 718 L50 SP Density Hydrometer | 0.70 to 0.75 g/ml, 335 mm, low surface tension
Brannan 10/462/0 | BS 718 L50 SP Density Hydrometer | 0.70 to 0.75 g/ml, 335 mm, low surface tension
Brannan 10/469/0 | BS 718 L50 SP Density Hydrometer | 1.05 to 1.10 g/ml, 335 mm, low surface tension
Brannan 10/469/0 | BS 718 L50 SP Density Hydrometer | 1.05 to 1.10 g/ml, 335 mm, low surface tension
Brannan 10/460/0 | BS 718 L50 SP Density Hydrometer | 0.60 to 0.65 g/ml, 335 mm, low surface tension
Brannan 10/460/0 | BS 718 L50 SP Density Hydrometer | 0.60 to 0.65 g/ml, 335 mm, low surface tension