Client Protection
Dedicated Support
Dwyer 3500-AL-20-NF-2 | Smart Differential Pressure Transmitter | 0 to 15 psi, ± 0.075 %, 4 to 20 mA
The Dwyer 3500-AL-20-NF-2 is a smart differential pressure transmitter: smart differential pressure transmitter, range 0-15 psi..
The Dwyer Series 3500 is a microprocessor-based smart differential pressure transmitter designed for flow measurement, level monitoring, filter or pump differential pressure applications, and critical process monitoring. The series measures compatible gases, steam, liquids, or vapors. The Series 3500 delivers an accuracy of ±0.075% FS (@20°C) with a stability of ≤0.075% FSO/3 years and rangeability up to 25:1 turn down. Thermal effects are compensated by transmitter software, specified as <±0.05% span/10°C.
- Accuracy: ± 0.075 %
- Accuracy Detail: ± 0.075% FS (@ 20°C)
- Compliance Note: CE 0518 II 2G ia/db IIC T6/T5 Gb Ta<80°C, T5 / II 2D Ex ia/tb IIIC T85°C/T100°C Db. EN 60079-0:2012+A11:2013,EN 60079-1:2014, EN 60079-11:2012, EN 60079-26:2015, EN 60079-31: Ex ia/db IIC T6/T5 Gb / Ex ia/tb IIIC T85°C/T100° Db. IEC 60079-0:2011, IEC 60079-1:2014-06, IEC 60079-11:2011, IEC 60079-26:2006, IEC 60079-31:2013.
- Damping Time: 0 to 60 s
- Electrical Connection: 1/2 in NPT female Conduit with Screw Terminal block
- Electrical Output: 4 to 20 mA
- Specifications
- Features
- Downloads
| Part Number | 3500-AL-20-NF-2 |
| Brand | Dwyer |
| Series | 3500 |
| Accuracy | ± 0.075 % |
| Accuracy Detail | ± 0.075% FS (@ 20°C) |
| Compliance Note | CE 0518 II 2G ia/db IIC T6/T5 Gb Ta<80°C, T5 / II 2D Ex ia/tb IIIC T85°C/T100°C Db. EN 60079-0:2012+A11:2013,EN 60079-1:2014, EN 60079-11:2012, EN 60079-26:2015, EN 60079-31: Ex ia/db IIC T6/T5 Gb / Ex ia/tb IIIC T85°C/T100° Db. IEC 60079-0:2011, IEC 60079-1:2014-06, IEC 60079-11:2011, IEC 60079-26:2006, IEC 60079-31:2013. |
| Damping Time | 0 to 60 s |
| Electrical Connection | 1/2 in NPT female Conduit with Screw Terminal block |
| Electrical Output | 4 to 20 mA |
| Enclosure Ratings | IP66, IP67, NEMA Type 4X |
| Long Term Stability | ≤0.075% FSO/3 years |
| MTBF | 1,000,000 hours |
| Materials | Aluminum |
| Measurement Pressure Type | Differential |
| Measurement Pressure, Max | 15 psi |
| Measurement Pressure, Min | 0 psi |
| Operating Temperature, Max | 85 °C |
| Operating Temperature, Min | -40 °C |
| Output Signal | Current |
| Process Connection Size | 1/4 in |
| Process Connection Type | NPT Female |
| Response Time | 16 to 480 ms |
| Supply Power Type | DC |
| Supply Voltage | 10 to 55 Vdc |
| Thermal Effects | < ± 0.05% span/10°C |
| Turndown Ratio | 25:1 |
| Country of Origin | Poland |
- Accuracy: ± 0.075 %
- Accuracy Detail: ± 0.075% FS (@ 20°C)
- Compliance Note: CE 0518 II 2G ia/db IIC T6/T5 Gb Ta<80°C, T5 / II 2D Ex ia/tb IIIC T85°C/T100°C Db. EN 60079-0:2012+A11:2013,EN 60079-1:2014, EN 60079-11:2012, EN 60079-26:2015, EN 60079-31: Ex ia/db IIC T6/T5 Gb / Ex ia/tb IIIC T85°C/T100° Db. IEC 60079-0:2011, IEC 60079-1:2014-06, IEC 60079-11:2011, IEC 60079-26:2006, IEC 60079-31:2013.
- Damping Time: 0 to 60 s
- Electrical Connection: 1/2 in NPT female Conduit with Screw Terminal block
Other models in this series
Click a row to open that product.
Related Products
Dwyer 629C-05-R5-P1-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-05-R5-P1-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-05-CH-P2-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-05-CH-P2-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-05-R1-P1-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-05-R1-P1-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-05-CH-P2-E5-S1 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 4 to 20 mA
Dwyer 629C-05-CH-P2-E5-S1 | Wet/Wet Differential Pressure Transmitter | 0 to 100 psi, ± 0.5 %, 4 to 20 mA
Dwyer 629C-04-CH-P2-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 50 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-04-CH-P2-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 50 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-03-CH-P2-E5-S1 | Wet/Wet Differential Pressure Transmitter | 0 to 25 psi, ± 0.5 %, 4 to 20 mA
Dwyer 629C-03-CH-P2-E5-S1 | Wet/Wet Differential Pressure Transmitter | 0 to 25 psi, ± 0.5 %, 4 to 20 mA
Dwyer 629C-02-R6-P1-E5-S1 | Wet/Wet Differential Pressure Transmitter | 0 to 10 psi, ± 0.5 %, 4 to 20 mA
Dwyer 629C-02-R6-P1-E5-S1 | Wet/Wet Differential Pressure Transmitter | 0 to 10 psi, ± 0.5 %, 4 to 20 mA
Dwyer 629C-03-CH-P2-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 25 psi, ± 0.5 %, 0 to 5Vdc
Dwyer 629C-03-CH-P2-E5-S3 | Wet/Wet Differential Pressure Transmitter | 0 to 25 psi, ± 0.5 %, 0 to 5Vdc