Client Protection
Dedicated Support
Genuine Products
Dwyer Instruments AVLV-2DM1-LCD | Air velocity transmitter | 2% accuracy | Duct mount | Modbus" communication with LCD display
A duct-mount air velocity transmitter with 2% accuracy, Modbus RTU/ASCII communication, field-selectable velocity ranges, and an onboard LCD display for local readings.
Request a quote in under a minute - call +971 6 5436933.
Part No. AVLV-2DM1-LCD
The Dwyer AVLV-2DM1-LCD is a duct-mount air velocity transmitter designed for integration with building management systems and HVAC control applications. It provides 2% accuracy across field-selectable velocity ranges of 100, 200, 300, or 400 FPM, equivalent to 0.5, 1, 1.5, or 2 m/s.
Modbus RTU/ASCII communication allows the transmitter to connect directly with compatible building management systems and controllers, making it suitable for VAV and AHU airflow monitoring and control applications.
A NEMA 4X (IP66) enclosure provides protection for installation in mechanical rooms and other suitable HVAC environments. The transmitter operates from 24 VDC or 24 VAC power and supports an operating temperature range of 32°F to 122°F (0°C to 50°C).
The AVLV-2DM1-LCD provides a typical response time of approximately four seconds, with faster response under constant temperature conditions. Its onboard 5-digit LCD allows technicians to view local air velocity readings during commissioning, installation, and field verification without requiring a laptop or separate display.
Need a different specification? The Dwyer range also includes the AVLV-2DM1, an air velocity transmitter with Modbus communication, so you can match the model to your exact application.
Ready to order the AVLV-2DM1-LCD? Speak to our team. Call +971 6 5436933.
Key Benefits
- 2% accuracy for duct air velocity measurement
- Modbus RTU/ASCII communication for BMS integration
- Field-selectable ranges of 100, 200, 300, or 400 FPM
- NEMA 4X (IP66) enclosure for suitable HVAC installations
- Onboard 5-digit LCD for local readings
- 24 VDC or 24 VAC power supply
- Suitable for VAV and AHU airflow monitoring and control
Who This Product Is Best For
- BMS integrators working with HVAC control systems
- Controls contractors installing VAV and AHU systems
- HVAC technicians monitoring duct air velocity
- Building automation professionals requiring Modbus communication
- Commissioning teams verifying airflow measurements locally and through a BMS
How to Use
- Install the AVLV-2DM1-LCD in the duct according to the appropriate probe installation practice.
- Connect the transmitter to a suitable 24 VDC or 24 VAC power supply.
- Connect the Modbus communication wiring to the compatible BMS or controller.
- Select the required velocity range of 100, 200, 300, or 400 FPM using the field configuration.
- Check the air velocity reading on the onboard 5-digit LCD and verify the measurement through the connected BMS.
Frequently Asked Questions
What accuracy does the AVLV-2DM1-LCD provide?
The AVLV-2DM1-LCD provides 2% accuracy across its field-selectable velocity ranges.
What velocity ranges can the AVLV-2DM1-LCD measure?
The transmitter can be configured for 100, 200, 300, or 400 FPM, equivalent to 0.5, 1, 1.5, or 2 m/s.
Does the AVLV-2DM1-LCD support Modbus?
Yes. This variant supports Modbus RTU/ASCII communication for integration with compatible building management systems and controllers.
What is the enclosure rating of the AVLV-2DM1-LCD?
The transmitter has a NEMA 4X (IP66) enclosure rating.
Does the AVLV-2DM1-LCD have a local display?
Yes. It includes a 5-digit LCD that allows technicians to view air velocity readings locally during installation and commissioning.
What power supply does the AVLV-2DM1-LCD require?
The transmitter operates on 24 VDC or 24 VAC power.
What applications is the AVLV-2DM1-LCD suitable for?
It is designed for duct air velocity measurement and is suitable for applications such as VAV and AHU airflow monitoring and HVAC control.
How can I get pricing for the AVLV-2DM1-LCD?
Pricing is quote-based. Call +971 6 5436933 to check current pricing and availability.
Does GeneralTech Shop deliver the AVLV-2DM1-LCD across the UAE?
Call +971 6 5436933 and our team will confirm delivery availability and timelines for your emirate.
Should I choose the AVLV-2DM1-LCD or AVLV-2DM1?
Both models are designed for duct air velocity measurement with Modbus communication. The AVLV-2DM1-LCD includes an onboard 5-digit LCD for local readings. Compare the display and application requirements before ordering.
For pricing or to place an order, contact GeneralTech Shop. Call +971 6 5436933.
- Specifications
- Features
- Downloads
| Accuracy | ±2% |
| Velocity Range | 100, 200, 300, 400 FPM (0.5, 1, 1.5, 2 m/s); field selectable |
| Approvals | BTL, CE |
| Connection | Communication: BACnet MS/TP or Modbus® RTU/ASCII: three-wire removable European-style terminal block for 16 to 26 AWG |
| Connection | Electrical: Analog: Power and output: four-wire removable European-style terminal block for 16 to 26 AWG Communication: BACnet MS/TP or Modbus® RTU/ASCII: three-wire removable European-style terminal block for 16 to 26 AWG |
| Current Consumption | 60 mA max |
| Device Load | 1/8 unit load |
| Display | 5-digit LCD (optional) |
| Enclosure Rating | NEMA 4X (IP66) |
| Humidity | 5 to 95% RH, non-condensing |
| Manufacturer | Dwyer Instruments |
| Material | Wetted: Consult factory |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Mounting | Flow direction must be parallel to the sensor tip |
| Output Load Resistance | Current output: 0 to 1100 Ω max.; Voltage output: minimum load resistance 1 kΩ |
| Output Signal | 4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC |
| Power Supply | 24 VDC ±20% or 24 VAC ±20% |
| Response Time | Approximately 4 seconds typical; 1 second at constant temperature |
| Type | Air Velocity Transmitter |
| Weight | 6.0 oz (160 g) |
- To ensure lifespan and durability, a tailored conformal coating has been applied to the sensing devices.
- Without the need for electricity, field configurable ranges can be readily established.
Related Products
Dwyer Instruments AVLV-2DM1 | Air velocity transmitter | 2% accuracy | Duct mount | Modbus" communication
Dwyer Instruments AVLV-2DM1 | Air velocity transmitter | 2% accuracy | Duct mount | Modbus" communication
Dwyer Instruments AVLV-2DB1-LCD | Air velocity transmitter | 2% accuracy | Duct mount | BACnet communication with LCD display
Dwyer Instruments AVLV-2DB1-LCD | Air velocity transmitter | 2% accuracy | Duct mount | BACnet communication with LCD display
Dwyer Instruments AVLV-2DB1 | Air velocity transmitter | 2% accuracy | Duct mount | BACnet communication
Dwyer Instruments AVLV-2DB1 | Air velocity transmitter | 2% accuracy | Duct mount | BACnet communication
Dwyer Instruments AVLV-2DA1-LCD | Air velocity transmitter | 2% accuracy | Duct mount | Universal current/voltage outputs with LCD display
Dwyer Instruments AVLV-2DA1-LCD | Air velocity transmitter | 2% accuracy | Duct mount | Universal current/voltage outputs with LCD display
Dwyer Instruments AVLV-2DA1 | Air velocity transmitter | 2% accuracy | Duct mount | Universal current/voltage outputs
Dwyer Instruments AVLV-2DA1 | Air velocity transmitter | 2% accuracy | Duct mount | Universal current/voltage outputs
Dwyer Instruments AVLV-1DM1-LCD | Air velocity transmitter | 1% accuracy | Duct mount | Modbus" communication with LCD display
Dwyer Instruments AVLV-1DM1-LCD | Air velocity transmitter | 1% accuracy | Duct mount | Modbus" communication with LCD display
Dwyer Instruments AVLV-1DM1 | Air velocity transmitter | 1% accuracy | Duct mount | Modbus" communication
Dwyer Instruments AVLV-1DM1 | Air velocity transmitter | 1% accuracy | Duct mount | Modbus" communication