Client Protection
Dedicated Support
Genuine Products
Dwyer HFS-2-10 | In-Line Flow Monitor | 0.5-10 GPM water, 1/2" female NPT, 303 SS
Scaled for water at 0.5-10 GPM (1.9-38 LPM), the Dwyer HFS-2-10 is an in-line flow monitor with 1/2" female NPT connections. Inside the HFS-2-10, a floating orifice disk and ring magnet travel along a tapered central shaft; a magnet follower outside the flow tube indicates the reading.
- Accuracy of the HFS-2-10: ±2% FS; repeatability ±1% FS
- Rated pressure (HFS-2-10): 1000 psig (70 bar) gas, 6000 psig (413 bar) liquid
- HFS-2-10 handles up to 240°F (116°C) and viscosities to 500 SSU
- 303 SS casing on the HFS-2-10, with FKM seals with PTFE backup, a PTFE-coated Alnico magnet and SS disk
- Shipping weight for the HFS-2-10 is 2 lb (0.9 kg)
- Specifications
- Features
- Downloads
| Part Number | HFS-2-10 |
| Brand | Dwyer |
| Type | In-line flow monitor (variable area) |
| Accuracy | ±2% FS |
| Repeatability | ±1% FS |
| Process Connection | 1/2" female NPT |
| Max. Operating Pressure | 1000 psig (70 bar) gas, 6000 psig (413 bar) liquid |
| Flow Range | 0.5-10 GPM (1.9-38 LPM) water |
| Other Wetted Parts | FKM seals with PTFE backup, PTFE-coated Alnico magnet, SS disk |
| Casing | 303 SS |
| Max. Temperature | 240 °F (116 °C) |
| Max. Viscosity | 500 SSU |
| Shipping Weight | 2 lb (0.9 kg) |
- Accurate performance with fluid viscosities up to 500 SSU is made possible by this special design.
- A sealed metal tube casing encloses all interior wetted sections, providing an almost maintenance-free machine.
- Greater application flexibility due to the lack of a straight piping requirement for the inlet or outlet and the ability to be installed in any orientation.
- High pressure and temperature ratings are possible due to the robust construction, which prolongs operation life.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer VA25437 | Variable Area Glass Flowmeter | Glass float, 18.39 SCFH air, 3.32 GPH water
Dwyer VA25437 | Variable Area Glass Flowmeter | Glass float, 18.39 SCFH air, 3.32 GPH water
Dwyer VA25435 | Variable Area Glass Flowmeter | Glass float, 8.07 SCFH air, 1.34 GPH water
Dwyer VA25435 | Variable Area Glass Flowmeter | Glass float, 8.07 SCFH air, 1.34 GPH water
Dwyer VA25431 | Variable Area Glass Flowmeter | Glass float, 1.75 SCFH air, 0.262 GPH water
Dwyer VA25431 | Variable Area Glass Flowmeter | Glass float, 1.75 SCFH air, 0.262 GPH water
Dwyer VA25429 | Variable Area Glass Flowmeter | Glass float, 0.792 SCFH air, 0.087 GPH water
Dwyer VA25429 | Variable Area Glass Flowmeter | Glass float, 0.792 SCFH air, 0.087 GPH water
Dwyer VA25425 | Variable Area Glass Flowmeter | Glass float, 0.104 SCFH air, 0.01 GPH water
Dwyer VA25425 | Variable Area Glass Flowmeter | Glass float, 0.104 SCFH air, 0.01 GPH water
Dwyer VA25037 | Variable Area Glass Flowmeter | Glass float, 18.39 SCFH air, 3.32 GPH water
Dwyer VA25037 | Variable Area Glass Flowmeter | Glass float, 18.39 SCFH air, 3.32 GPH water
Dwyer VA25035 | Variable Area Glass Flowmeter | Glass float, 8.07 SCFH air, 1.34 GPH water
Dwyer VA25035 | Variable Area Glass Flowmeter | Glass float, 8.07 SCFH air, 1.34 GPH water
Dwyer VA25031 | Variable Area Glass Flowmeter | Glass float, 1.75 SCFH air, 0.262 GPH water
Dwyer VA25031 | Variable Area Glass Flowmeter | Glass float, 1.75 SCFH air, 0.262 GPH water