Client Protection
Dedicated Support
Genuine Products
Dwyer RHP-3D1A | Duct Humidity/Temperature Transmitter | ±3% RH, 4-20 mA RH, 10K Thermistor
Dwyer RHP-3D1A is a duct-mount transmitter rated ±3% (20 to 80% RH @ 25°C), providing a 4-20 mA humidity output plus a passive 10K @ 25°C thermistor temperature output. A capacitance polymer sensor handles humidity measurement in the Series RHP RHP-3D1A.
- Supply for the 4-20 mA version: 10-35 VDC (loop powered) (RHP-3D1A)
- RHP-3D1A: 10K Thermistor temperature sensor accuracy ±0.2°C @ 25°C (±0.36°F @ 77°F)
- Measures 0 to 100% RH; drift below 1% RH per year, hysteresis ±1%, response time 15 s on the RHP-3D1A
- Duct mount: NEMA 4X (IP66) housing, 1/2" NPS conduit connection, 0.616 lb (0.3 kg) (RHP-3D1A)
- RHP-3D1A: Operating range -40 to 140°F (-40 to 60°C)
- Specifications
- Features
- Downloads
| Part Number | RHP-3D1A |
| Brand | Dwyer |
| Series | RHP |
| Power | 10-35 VDC (loop powered) |
| Response Time | 15 s |
| Drift | <1% RH/year |
| Mounting | Duct mount |
| RH Accuracy | ±3% (20 to 80% RH @ 25 °C) |
| RH Range | 0 to 100% RH |
| Weight | 0.616 lb (0.3 kg) |
| RH Output | 4-20 mA |
| Temperature Output | 10K @ 25 °C thermistor |
| Enclosure Rating | NEMA 4X (IP66) (housing only) |
| Temperature Accuracy | ±0.2 °C @ 25 °C (±0.36 °F @ 77 °F) |
- Lower installation costs when temperature and humidity are combined.
- With 2%, 3%, and 5% accuracy and a wide range of temperature sensors, there is a wide application environment.
- Lower system operating costs thanks to the radiation barrier that shields the sensor from heat radiation.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer HS-412 | Humidity Switch | 4 to 20 mA, ± 1 % RH
Dwyer HS-412 | Humidity Switch | 4 to 20 mA, ± 1 % RH
Dwyer HS-311 | Humidity Switch | 0 to 3 V, ± 1 % RH
Dwyer HS-311 | Humidity Switch | 0 to 3 V, ± 1 % RH
Dwyer HS-312 | Humidity Switch | 0 to 3 V, ± 1 % RH
Dwyer HS-312 | Humidity Switch | 0 to 3 V, ± 1 % RH
Dwyer HS-112 | Humidity Switch | 0 to 1 V, ± 1 % RH
Dwyer HS-112 | Humidity Switch | 0 to 1 V, ± 1 % RH
Dwyer HS-111 | Humidity Switch | 0 to 1 V, ± 1 % RH
Dwyer HS-111 | Humidity Switch | 0 to 1 V, ± 1 % RH
Dwyer HS-411 | Humidity Switch | 4 to 20 mA, ± 1 % RH
Dwyer HS-411 | Humidity Switch | 4 to 20 mA, ± 1 % RH
Dwyer THC-31 | Temperature/Humidity Switch | -50 to 150 °C
Dwyer THC-31 | Temperature/Humidity Switch | -50 to 150 °C
Dwyer THC-30 | Temperature/Humidity Switch | -58 to 302 °F
Dwyer THC-30 | Temperature/Humidity Switch | -58 to 302 °F