These tiny transmitters mount inside of a typical probe-head housing. They monitor temperature changes and send information to a remote monitoring display, control panel, or control room via an attached RTD or thermocouple. They are frequently used in industrial processes where a smaller device is needed.

Free UAE shipping available
- Specifications
- Features
Accuracy | +/-0.2°C plus 0.2% reading |
Power Supply | 10 to 32V DC |
Range | 32 to 212 Degrees F |
Storage Temperature | 160°F (70°C) |
DWYER Temperature Transducer
Range 32 to 212 Degrees F
10 to 32V DC, 651
Pt100 RTD, 4 to 20mA DC
Screw Terminals
Related Products

Dwyer Instruments CDTR-2D4F4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & 20 kO thermistor temperature output

Dwyer Instruments CDTR-2D4F4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & 20 kO thermistor temperature output

Dwyer Instruments CDSN | Carbon Dioxide/Temperature transmitter | Wall mount | Universal current/voltage output | 2000 PPM

Dwyer Instruments CDSN | Carbon Dioxide/Temperature transmitter | Wall mount | Universal current/voltage output | 2000 PPM

Dwyer Instruments RHP-2O22 | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and 0-10 VDC temperature output

Dwyer Instruments RHP-2O22 | OSA mount 2% RH/temperature transmitter with 0-10 VDC RH output and 0-10 VDC temperature output

DWYER Temperature Transducer | Range 32 to 752 Degrees F | 10 to 32V DC | Type K Thermocouple | 4 to 20mA DC | Screw Terminals

DWYER Temperature Transducer | Range 32 to 752 Degrees F | 10 to 32V DC | Type K Thermocouple | 4 to 20mA DC | Screw Terminals

DWYER Temperature Transducer | Range 32 to 392 Degrees F | 10 to 32V DC, | Type K Thermocouple | 4 to 20mA DC | Screw Terminals,

DWYER Temperature Transducer | Range 32 to 392 Degrees F | 10 to 32V DC, | Type K Thermocouple | 4 to 20mA DC | Screw Terminals,

DWYER Temperature Transducer | Range 32 to 212 Degrees F | 10 to 32V DC, 651 | Type K Thermocouple, 4 to 20mA DC | Screw Terminals,

DWYER Temperature Transducer | Range 32 to 212 Degrees F | 10 to 32V DC, 651 | Type K Thermocouple, 4 to 20mA DC | Screw Terminals,

DWYER Temperature Transducer | Range 32 to 752 Degrees F | 10 to 32V DC, 651 | Pt100 RTD, 4 to 20mA DC | Screw Terminals,

DWYER Temperature Transducer | Range 32 to 752 Degrees F | 10 to 32V DC, 651 | Pt100 RTD, 4 to 20mA DC | Screw Terminals,