Client Protection
Dedicated Support
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
The C581 flow and energy computer measures the actual flow, temperature and pressure and uses the IAPWS determinations or Water-Glycol tables to calculate the energy, mass and volumetric flow. The linearization enhances accuracy in any flow range. The large logging register contains all measured and calculated values. Typical use: For industrial environments, measuring coolants, water, superheated and saturated steam at heat exchangers, boilers, condensers and coolers.
Key features
- Media: Coolants / water-Glycol mixtures, water and saturated / superheated steam.
- Displays calculated mass flow, volumetric flow and power at actual conditions.
- Calculates totalized values for volume, mass and energy.
- Determines density and enthalpy according to IAPWS.
- For single stream applications.
- Main screen with custom selectable order of measured and calculated variables.
- Data logging of process parameters and calculated values.
- Specifications
- Downloads
| Part Number | C581 |
| Brand | Fluidwell |
| Product Type | Flow & Energy Computer |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | One HF pulse input: NAMUR, Coil, PNP, NPN, Reed sensor or active input.; One to three analog inputs: 4 - 20mA active or passive. Also suitable for 2 or 3 stacked dP sensors. |
| Supply - Power Supply | 16 – 27V DC; 100 – 230V AC. |
| Supply - Sensor Supply | Analog inputs: >20V DC when active.; Pulse inputs: 5.4 – 8.2 – 12 – 22V DC. |
| Signal Inputs - Status Inputs | Two configurable inputs for e.g. external alarms. |
| Signal Outputs - Pulse Outputs | Function: Two configurable pulse outputs, selectable from a list of calculated values. Frequency max. 2kHz.; Type: Two passive transistor outputs. |
| Signal Outputs - Analog Outputs | Function: Re-transmitting analog values, selectable from a list of calculated values.; Type: One or two configurable active / passive isolated 4 – 20mA outputs. |
| Communication | Function: Reading display info, read/write configuration settings, data log extraction, firmware uploads (via USB only). Protocol: Modbus RTU. Interface: USB, RS232 and RS485 2-wire. |
| Signal Inputs - Temperature Inputs | Two Pt100, Pt500, Pt1000 (2-, 3- or 4-wire) inputs with Callendar-van Dusen equation.; Two 4 – 20 mA (active/passive) inputs. |
| Signal Inputs - Pressure Inputs | One analog input: 4 - 20mA active or passive input. |
| Signal Outputs - Alarm Outputs | Function: Configurable for various errors or warning, selectable from a list of events, measured and calculated values.; Type: Two passive transistor outputs and two relay outputs. |
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Nuflo MC II Analyser | Flow Indicator
Nuflo MC II Analyser | Flow Indicator
Nuflo MC III Analyser | Flow Indicator
Nuflo MC III Analyser | Flow Indicator
Dwyer SFI-801-3/4-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4 | Polycarbonate Sight Flow Indicator | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4 | Polycarbonate Sight Flow Indicator | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-1/2-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 2-20 GPM, 1/2" female NPT
Dwyer SFI-801-1/2-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 2-20 GPM, 1/2" female NPT