Client Protection
Dedicated Support
Fluidwell F074 | Intrinsically Safe Level / Pump Controller | with one control output, ambient -40°C to +70°C
The F074 is a basic level indicator / pump controller that works with a preset value and two switch points to control a pump or valve. The low and high level switch points are entered as a percentage of the preset value to switch the device on / off. For pump control applications, the function can be inverted to empty a well. Typical use: Basic on / off level control applications without PI(D) control requirements. Also very suitable for applications where the required level changes frequently.
Key features
- The display shows the actual level, preset value, high / low switch points and status.
- On-screen engineering units are easily configured from a comprehensive selection.
- Selectable on-screen engineering units for level: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
- Selectable on-screen engineering units for height: mm, cm, m, mtr, inch, ft, mmwk, mmwc, cmwk, cmwc, mwk, mwc, inwc, ftwc, mBar, Bar, PSI or no unit.
- Level: six large 17mm (0.67") digits.
- LED backlight with adjustable intensity.
- Level control: high / low switch points and a preset value can be set.
- Specifications
- Downloads
| Part Number | F074 |
| Brand | Fluidwell |
| Product Type | Level / Pump Controller |
| Enclosure / Area | Safe area / Intrinsically safe |
| Ambient Temperature | -40°C to +70°C |
| Signal Inputs - Level Inputs | (0)4 – 20mA. |
| Signal Outputs - Control outputs | Function: Control output to control a pump or valve, according to the high / low level switch point values.; Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA, input Loop-powered.; 8 – 24V AC/DC.; 115 – 230V AC.; Basic: 8 - 30V DC. |
| Supply - Sensor Supply | 8.2, 12, 24V DC. |
| Hazardous Area - Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da; IECEx: Gas: Ex ia IIC T4 Ga Dust: Ex ia IIIC T200 100 °C Da; CSA: I.S. Class I/II/III, Div 1, Grp A...G, T4 Class I, Zone 0, AEx ia IIC T4 Ga Note: Extended aluminum enclosures not available with CSA/FM approval. |
Related Products
Fluidwell F175 | Level / Pump Controller, Open Channel Flow Monitor | with configurable analog and control / alarm output
Fluidwell F175 | Level / Pump Controller, Open Channel Flow Monitor | with configurable analog and control / alarm output
Fluidwell F173 | Level Monitor / Controller | with linearization, analog, control and alarm outputs
Fluidwell F173 | Level Monitor / Controller | with linearization, analog, control and alarm outputs
Fluidwell F174 | Level / Pump Controller | with pump-control and level-alarm outputs
Fluidwell F174 | Level / Pump Controller | with pump-control and level-alarm outputs
Fluidwell F170 | Level Monitor | with high / low alarms and analog outputs
Fluidwell F170 | Level Monitor | with high / low alarms and analog outputs
Fluidwell F077 | Intrinsically Safe Level Monitor | with linearization and one high / low alarm output, ambient -40°C to +70°C
Fluidwell F077 | Intrinsically Safe Level Monitor | with linearization and one high / low alarm output, ambient -40°C to +70°C
Fluidwell F070 | Intrinsically Safe Level Indicator | with very large digits, ambient -40°C to +70°C
Fluidwell F070 | Intrinsically Safe Level Indicator | with very large digits, ambient -40°C to +70°C
Fluidwell F073 | Intrinsically Safe Level Monitor | with one high / low alarm output, ambient -40°C to +70°C
Fluidwell F073 | Intrinsically Safe Level Monitor | with one high / low alarm output, ambient -40°C to +70°C