FLUIDWELL F116 | Intrinsically safe - Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
The F116 flow computer was designed to compute total volume, differential, or consumption. In these kinds of applications, pulsing flows, extremely low consumption values, vibration, and high ambient temperatures are typical problems. All of these are well taken care of in the F116's construction and functionality. The computed differential or total value is reflected in the pulse and analog outputs.
Flow rate, total, and cumulative total are displayed on the display. From a wide assortment, on-screen engineering units are simple to configure.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Flowmeter Inputs Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. Different pulse signal types are allowed for input A and B. |
Power Supply | Long life Lithium battery. 4 " 20mA Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply 3.2, 8.2, 12, 24V DC. |
- computes the cumulative total, total flow, and differential flow rate (consumption) of flows A and B.
- Determines the cumulative total, total flow rate, and sum of flows A and B.
- safeguards against extremely low consumption figures and pulsing flows.
- Pulse and analog outputs.
- Flow rate, difference or summerized total, and accumulated total are displayed on the screen.
- Large digit selection available for total or flow rate.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct engineering units on the display for the total and flow rate.
- LED backlighting.
- intrinsic safety as defined by IECEx and ATEX.
- Enclosures made of GRP, aluminum, or premium stainless steel.
- EEPROM memory is used for automatic setting and running total backups.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT