Client Protection
Dedicated Support
Palmer Wahl 9FL | Economy Industrial Thermometer, Plastic Case, 9FL | 9 in
Palmer Wahl 9FL economy industrial thermometers use a 9 in (220 mm) black molded high-temperature plastic case, paired with 3.5 or 6 in cast aluminium stems. A white V-shaped aluminium scale with bold black markings reads to ±1 scale division, and NIST calibration can be provided on request. Choose red-reading mercury or mercury-free Sky Blue (SB) fill.
Key features
- Molded high-temperature plastic case, glass crystal
- Tapered bulb chamber for tapered thermowells
- Industry-standard 1-1/4 in-18 UNEF brass swivel nut
- Two-screw all-angle adjustment
- F or dual F & C scales, -40 to 400°F
A 6 in air duct version has a perforated 3/4 in aluminium guard around a bare bulb for circulating air. Sky Blue fill is offered up to 300°F.
- Specifications
- Downloads
| Part Number | 9FL |
| Brand | Palmer Wahl |
| Case | 9 in (220 mm) molded plastic, black |
| Crystal | Glass |
| Fill | Red-reading mercury or Sky Blue liquid |
| Accuracy | ±1 scale division |
| Calibration | NIST on request |
| Fitting | 1-1/4 in-18 UNEF brass swivel nut |
| Stem | Cast aluminium, 3.5 or 6 in |
| Bulb | Tapered chamber; air duct (6 in only) |
| Ranges | -40/110°F to 50/400°F, F or F&C |
Related Products
Center 307 | Thermometer | Range -200~1370℃ ; -328~2498℉, Accuracy ±0.3%rdg+1℃ ; ±0.3%rdg+2℉
Center 307 | Thermometer | Range -200~1370℃ ; -328~2498℉, Accuracy ±0.3%rdg+1℃ ; ±0.3%rdg+2℉
Center 308 | Dual Input Thermometer | Range -200~1370℃ ; -328~2498℉, Accuracy ±0.3%rdg+1℃ ; ±0.3%rdg+2℉
Center 308 | Dual Input Thermometer | Range -200~1370℃ ; -328~2498℉, Accuracy ±0.3%rdg+1℃ ; ±0.3%rdg+2℉
Center 304 | Four Channels Thermometer | Range -200~1370℃ ; -328~2498℉, Accuracy ±0.3%rdg+1℃ ; ±0.3%rdg+2℉
Center 304 | Four Channels Thermometer | Range -200~1370℃ ; -328~2498℉, Accuracy ±0.3%rdg+1℃ ; ±0.3%rdg+2℉
Center 303 | Dual Input Thermometer | Range K type: -200~1370℃, Accuracy ±0.1%+0.7℃, ±0.1%+1.4℉
Center 303 | Dual Input Thermometer | Range K type: -200~1370℃, Accuracy ±0.1%+0.7℃, ±0.1%+1.4℉
Center 301 | Dual Input Thermometer | Range K type: -200~1370℃ ; -328~2498℉, Accuracy ±0.3%+1℃, ±0.3%+1.8℉
Center 301 | Dual Input Thermometer | Range K type: -200~1370℃ ; -328~2498℉, Accuracy ±0.3%+1℃, ±0.3%+1.8℉
Center 302 | Thermometer | Range K type: -200~1370℃, Accuracy ±0.1%+0.7℃, ±0.1%+1.4℉
Center 302 | Thermometer | Range K type: -200~1370℃, Accuracy ±0.1%+0.7℃, ±0.1%+1.4℉
KIMO KIRAY 300 | Infrared thermometer | -50 to 1850 °C, 50:1
KIMO KIRAY 300 | Infrared thermometer | -50 to 1850 °C, 50:1
KIMO TM 210 | Multi-channel thermometer | 2 x Pt100, 4 x thermocouple
KIMO TM 210 | Multi-channel thermometer | 2 x Pt100, 4 x thermocouple