Client Protection
Dedicated Support
Genuine Products
Vaisala DMP6 Dew Point Probe | Dew Point Probe for Very High Temperatures | Td -25 to +100 °C
The Vaisala DMP6 dew point probe is intended for very high temperature applications and measures dew point from -25 to +100 °C (-13 to +212 °F) with ±2 °C accuracy.
- DRYCAP sensor tolerates condensation, most chemicals, oil vapour and particles
- Sensor warming limits moisture build-up
- Automatic calibration adjustment in dry conditions
- Works with Indigo500 and Indigo200 series transmitters
- Vaisala Insight PC software for configuration, calibration and data display
- Accuracy ±2 °C (±3.6 °F)
- Specifications
- Features
- Downloads
| Part Number | DMP6 Dew Point Probe |
| Brand | Vaisala |
| Accuracy | ±2 °C (±3.6 °F) |
| Dew Point | -25 to +100 °C (-13 to +212 °F) Td |
Vaisala DMP6 Dew Point Probes
- Dew point measurement accuracy up to ±2 °C (±3.6 °F)
- Sensor purge provides superior chemical resistance
- Withstands condensation, oils, dust and most chemicals
- Modbus RTU over RS-485 for flexible connectivity
- Includes traceable three-point calibration certificate
- Long (two-year) calibration interval for easy maintenance
- Use with Indigo transmitters for best functionality, including display and analogue output
- In-line measurement for humidity at temperatures up to +350 °C (+662 °F)
- Dew point measurement range -25 … +100 °C (-13 … +212 °F) Td
Related Products
Vaisala MMT143 | Moisture and Temperature Transmitter for Oil | Water activity (aw), IP66 stainless steel, RS-485 Modbus
Vaisala MMT143 | Moisture and Temperature Transmitter for Oil | Water activity (aw), IP66 stainless steel, RS-485 Modbus
Vaisala Optimus OPT100 | Dissolved Gas Analysis (DGA) Monitor | Multi-gas DGA, Total gas pressure method, IP66
Vaisala Optimus OPT100 | Dissolved Gas Analysis (DGA) Monitor | Multi-gas DGA, Total gas pressure method, IP66
Vaisala MHT410 | Moisture, Hydrogen and Temperature Transmitter | Hydrogen and moisture, IP66, DNP3.0 and Modbus RTU
Vaisala MHT410 | Moisture, Hydrogen and Temperature Transmitter | Hydrogen and moisture, IP66, DNP3.0 and Modbus RTU
Vaisala MMT310 | Moisture and Temperature Meter for Oil | Water activity in oil, HUMICAP sensor, Ball valve install
Vaisala MMT310 | Moisture and Temperature Meter for Oil | Water activity in oil, HUMICAP sensor, Ball valve install
Vaisala Indigo202 | Indigo200 Series Transmitter, RS-485 Modbus RTU, Display | RS-485 Modbus RTU, Built-in display, Probe host device
Vaisala Indigo202 | Indigo200 Series Transmitter, RS-485 Modbus RTU, Display | RS-485 Modbus RTU, Built-in display, Probe host device
Vaisala Indigo201 | Indigo200 Series Transmitter, 3 Analog Outputs | 3 analog outputs (mA/V), Probe host device, USB config
Vaisala Indigo201 | Indigo200 Series Transmitter, 3 Analog Outputs | 3 analog outputs (mA/V), Probe host device, USB config
Vaisala MGP241 | Multigas CO2 Instrument for CCUS | 0…100 vol-% CO2, 0…25 vol-% H2O, IP65
Vaisala MGP241 | Multigas CO2 Instrument for CCUS | 0…100 vol-% CO2, 0…25 vol-% H2O, IP65
Vaisala MGP261 | CH4, CO2 and Humidity Multigas Probe for Biogas | CH4, CO2 and humidity, Ex certified, In-situ biogas measurement
Vaisala MGP261 | CH4, CO2 and Humidity Multigas Probe for Biogas | CH4, CO2 and humidity, Ex certified, In-situ biogas measurement