Wohler DC 410 FLOW | Pressure Differential & Flow Meter
One device to detect temperature, relative humidity, air movement, and pressure.
'Ventilation for buildings - test procedures & measuring methods for handing over installed ventilation and air conditioning systems' is tested to meet standards.

Free UAE shipping available
- Specifications
- Downloads
Operating Temperature | 5¦40 °C |
PRESSURE | Differential Pressure Range +/-100 hPa Accuracy < 3 % of the reading, if the value is < +/-5 Pa, better than +/-0,15 Pa Resolution 0,01 Pa within the range +/-110 Pa 0,1 Pa within the range +/-1.000 Pa otherwise 1 Pa |
Relative Humidity | Relative humidity Range 0¦100 % r.H. (relative humidity), non condensing Accuracy < +/-2 % r.H., at 0¦90 % r.H., otherwise < 3 % r.H. Resolution 0,1 % r.H. |
Temperature | Range -20¦60 °C Accuracy < +/-1 °C Resolution 0,1 °C |
Related Products

Dwyer Instruments GFC-2143 | Gas mass flow controller | Range 0-200 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2143 | Gas mass flow controller | Range 0-200 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2142 | Gas mass flow controller | Range 0-100 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2142 | Gas mass flow controller | Range 0-100 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2133 | Gas mass flow controller | Range 0-50 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2133 | Gas mass flow controller | Range 0-50 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2131 | Gas mass flow controller | Range 0-30 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2131 | Gas mass flow controller | Range 0-30 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2111 | Gas mass flow controller | Range 0-15 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2111 | Gas mass flow controller | Range 0-15 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2109 | Gas mass flow controller | Range 0-5 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2109 | Gas mass flow controller | Range 0-5 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2108 | Gas mass flow controller | Range 0-2 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2108 | Gas mass flow controller | Range 0-2 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting