Barton Two Pen Pressure Temperature Recorder, Model 242E, Pressure Range: 0-30000 Psi, Battery Driven Chart Drive: 11 Selectable Speeds
Genuine Barton 242E/0-30000 Psi-100C/Battery barton 242e two-pen pressure & temperature recorder, in stock at General Tech Services LLC, UAE. Pressure Range: 0-30000 Psi; Temperature Range: 0-100 Deg C; Clock: Battery Driven Chart Drive: 11 Selectable Speeds. Free UAE shipping.
Request a quote in under a minute - call +971 6 5436933.
Part No. 242E/0-30000 Psi-100C/Battery | 0-30000 Psi
The Barton Model 242E Two Pen Pressure & Temperature Recorder is a 12-inch (300mm) chart recorder built to log both process pressure and temperature on the same chart at the same time, using a red pressure pen and a blue temperature pen. Perfected construction techniques ensure linearity, low hysteresis and a long service life, backed by a die-cast aluminum case with stainless steel linkage that stands up to industrial and outdoor environments. A disposable felt-tip inking system keeps maintenance simple, and the standard 2-inch pipe mount lets it install directly onto existing process piping.
Ready to order the 242E/0-30000 Psi-100C/Battery? Speak to our team. Call +971 6 5436933
Key Benefits
- Records pressure and temperature on the same chart from one unit
- Perfected construction techniques ensure linearity, low hysteresis and a long service life
- Die-cast aluminum case with stainless steel linkage for industrial and outdoor duty
- Standard 12 inch (300mm) circular charts for easy, low-cost record replacement
- Disposable felt-tip inking system keeps maintenance simple
Who This Product Is Best For
- Sites needing a single chart record of both pressure and temperature at one point
- Facilities standardising on Barton chart recorders across combined
- pressure/temperature duty Sites needing a specific chart-drive speed (2hr/8hr, 24hr/7day, or 11-speed battery) to match logging duration
How to Specify & Commission It
- Confirm the recorder's range and chart-drive type match your process and required logging interval.
- Mount the unit on its 2 inch pipe connection at the measurement point.
- Load a chart of the correct range and fit a fresh felt-tip pen for each pen position.
- Set the chart drive (wind the mechanical clock or fit a fresh battery) and confirm the pen traces cleanly before leaving it logging.
Frequently Asked Questions
What pressure range does this Barton 242E cover?
This unit is rated for a pressure range of 0-30000 Psi, with a 0-100 deg c.
What does the second pen record?
The first (red) pen records pressure over the range shown above; the second (blue) pen records temperature over a fixed 0- 100 Deg C range, both on the same chart.
Can I get a different temperature range on the second pen?
This listing is fixed at 0-100 Deg C for the temperature pen; contact our team if your application needs a different combination.
What size chart does it use?
A standard 12 inch (300mm) nominal diameter circular chart.
How is the recorder mounted?
On a standard 2 inch pipe mount, so it installs directly onto existing process piping.
Mechanical or battery chart drive - which should I choose?
Mechanical drives (2hr/8hr or 24hr/7day) wind up and need no power source; battery driven units with 11 selectable speeds give more flexibility over the logging interval but need a working battery. Pick based on your site's logging cycle and power access.
Should I choose the 242E/0-30000 Psi-100C/Battery or the 242E/0-25000 Psi-100C/Battery?
Compare the headline specifications above against your process requirements. The 242E/0-25000 Psi-100C/Battery differs in rating from the 242E/0-30000 Psi-100C/Battery; contact our team and we'll confirm the exact match for your application.
For pricing or to place an order, contact General Tech Services LLC. Call +971 6 5436933