Client Protection
Dedicated Support
Dwyer 655A-07-P | Fixed Range Differential Pressure Transmitter | 0 to 2 psid, 4-20 mA DC or 1-5 VDC
The Dwyer 655A-07-P is a fixed range differential pressure transmitter.
The Series 655A 316 Wet/Wet Differential Pressure Transmitter is designed for high static/low DP applications designed especially for the End Users and OEM’s where extreme overpressure and high performance of 0.25% accuracy and stability are required at ranges down to 3 in w.c. Each unit includes a 6-point NIST certificate of calibration which demonstrates the unit’s high level of performance.
- Range: 0 to 2 psid
- Service: Compatible gases, liquids, or vapors
- Wetted Materials: Types 316L SS
- Accuracy: BFSL: ±0.5% FS (includes linearity, hysteresis, and repeatability)
- Stability: ±1.0 FS/yr
- Pressure Limits: 3 x FS differential pressure;
- Specifications
- Features
| Part Number | 655A-07-P |
| Brand | Dwyer |
| Series | 655A |
| Range | 0 to 2 psid |
| Accuracy | BFSL: ±0.5% FS (includes linearity, hysteresis, and repeatability) |
| Weight | 18 oz (510 g) |
| Service | Compatible gases, liquids, or vapors |
| Wetted Materials | Types 316L SS |
| Stability | ±1.0 FS/yr |
| Pressure Limits | 3 x FS differential pressure; |
| Burst | 2500 psig |
| Temperature Limits | Ambient operating: -40 to 140 °F (-40 to 60 °C); |
| Process Interface | -40 to 212 °F (-40 to 100 °C); |
| Storage | -40 to 212 °F (-40 to 100 °C) |
| Compensated Temperature Range | -20 to 160 °F (-29 to 71 °C) |
| Thermal Effect | ±2% FS/50 °F (reference to 77 °F) |
| Power Requirements | 12-30 VDC for 4-20 mA outputs; 8-14 VDC for 1-5 VDC outputs, both with reverse polarity protection |
| Output Signal | 4-20 mA DC or 1-5 VDC |
| Compensated Temperature Limits | 0 to 170 °F (-17.8 to 76.7 °C) |
| Thermal Effects | ≤ ±1.5% FS oven comp. temperature range |
| Static Pressure Effects | On zero: ≤ ±0.25% FSO per 1000 psi; on span: ≤ ±0.5% of reading per 1000 psi |
| Response Time | < 10 ms |
| Loop Resistance | 1500 Ω |
| Electrical Connections | Cable exit with 24˝ cable; optional 6-pin connector |
| Process Connections | 1/4˝ NPT female |
| Enclosure Rating | Designed to meet NEMA 4X (IP66) |
| Mounting Orientation | Mount in vertical position: zero shifts up to ±1 in w.c. depending on orientation |
- Range: 0 to 2 psid
- Service: Compatible gases, liquids, or vapors
- Wetted Materials: Types 316L SS
- Accuracy: BFSL: ±0.5% FS (includes linearity, hysteresis, and repeatability)
- Stability: ±1.0 FS/yr
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer RSMC-B-014-SS | StabiliSENSE™ Critical Room Status Monitor | -0.5 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-014-SS | StabiliSENSE™ Critical Room Status Monitor | -0.5 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-003-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-003-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-B-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-B-002-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.25 inH₂O, ± 0.5 %
Dwyer RSMC-B-002-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.25 inH₂O, ± 0.5 %
Dwyer RSMC-A-004-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-A-004-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-B-015 | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-B-015 | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-A-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-A-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-B-013-SS | StabiliSENSE™ Critical Room Status Monitor | -0.25 to 0.25 inH₂O, ± 0.5 %
Dwyer RSMC-B-013-SS | StabiliSENSE™ Critical Room Status Monitor | -0.25 to 0.25 inH₂O, ± 0.5 %