The Dwyer A-RH2-CP-R is a room humidity transmitter: relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, 10K Ohm Thermistor (Type II).
- Accuracy: ± 2 %
- Current, Max: 8 mA
- Electrical Connection: Screw Terminal
- Electrical Output: 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc
- Enclosure Material: ABS Plastic
- Filter: Hydrophobic Filter
- Specifications
- Features
- Downloads
| Part Number | A-RH2-CP-R |
| Brand | Dwyer |
| Series | RH-Combo-Room-Thermistor |
| Response Time | 20 Seconds Typical |
| Weight | 19.17 lb |
| Accuracy | ± 2 % |
| Filter | Hydrophobic Filter |
| Enclosure Material | ABS Plastic |
| Current, Max | 8 mA |
| Electrical Connection | Screw Terminal |
| Electrical Output | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc |
| Height | 4.5 in |
| Length | 2.75 in |
| Measurement Type | Humidity |
| Mounting Orientation | -R Enclosure (Beige) |
| Operating Temperature, Max | 60 °C (140 °F) |
| Operating Temperature, Min | 1.5 °C (34.7 °F) |
| Output Detail | 0-5 VDC: 12 - 40 VDC / 18 - 28 VAC |
| Relative Humidity | 0 to 95% |
| Relative Humidity Accuracy | ± 2% RH |
| Relative Humidity Sensor Type | Capacitive with Hydrophobic Filter |
| Repeatability | 0.5% RH,± 0.05 °C |
| Sensitivity | 0.1% RH |
| Stability | RH Stability: Less than 2% drift / 5 years,Platinum RTD Stability: +/-0.03% after 1000 Hours @ 572 °F (300 °C) |
| Storage Temperature, Max | 65 °C (149 °F) |
| Storage Temperature, Min | -40 °C (-40 °F) |
| Supply Power Type | DC |
| Supply Voltage | 24 Vdc |
| Temperature Sensor Type | 10 kΩ Type II Thermistor |
| Tightening Torque | 4.43 to 5.31 lb-in (0.5 to 0.6 Nm) |
| Width | 1.12 in |
| Wire Gauge | 26 to 16 AWG |
| Country of Origin | United States |
- Accuracy: ± 2 %
- Current, Max: 8 mA
- Electrical Connection: Screw Terminal
- Electrical Output: 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc
- Enclosure Material: ABS Plastic
Other models in this series
Click a row to open that product.
Related Products
Dwyer A-RH3-1K-NI-O | Outside Air Humidity Transmitter | ±3% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH3-1K-NI-O | Outside Air Humidity Transmitter | ±3% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH3-1K-2W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH3-1K-2W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH3-1K-3W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Three Wires)
Dwyer A-RH3-1K-3W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Three Wires)
Dwyer A-RH1-1K-NI-O | Outside Air Humidity Transmitter | ±1% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH1-1K-NI-O | Outside Air Humidity Transmitter | ±1% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH2-R-LCD-010 | Room Humidity Transmitter with LCD | ±2% RH, 0-10 VDC
Dwyer A-RH2-R-LCD-010 | Room Humidity Transmitter with LCD | ±2% RH, 0-10 VDC
Dwyer A-RH3-R-LCD-010 | Room Humidity Transmitter with LCD | ±5% RH, 0-10 VDC
Dwyer A-RH3-R-LCD-010 | Room Humidity Transmitter with LCD | ±5% RH, 0-10 VDC
Dwyer A-RH2-1K-2W-R | Room Humidity Transmitter | ±2% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH2-1K-2W-R | Room Humidity Transmitter | ±2% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH1-1K-2W-R | Room Humidity Transmitter | ±1% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH1-1K-2W-R | Room Humidity Transmitter | ±1% RH, 1K Ohm RTD (Two Wires)