Client Protection
Dedicated Support
Dwyer AC1904 | PT100 Temperature Probe | -50 to 105 °C
The Dwyer AC1904 is a PT100 temperature probe: high accuracy Temperature measurement according to IEC751.
The Rotronic Series AC19XX comprises PT100 Class A temperature probes designed for industrial and pharmaceutical applications. According to the product overview, these sensors are suitable for storage monitoring of pharmaceuticals, production processes, drying operations, and incoming goods inspection. The series utilizes a Sensor PT100 Class A element with an accuracy class defined as -30...300 °C according to IEC751. The uncertainty for this range is specified as U = ± (0.15 + 0.0021 * |T|). For temperatures outside the Class A range, the uncertainty is listed as U = ± (0.30 + 0.005 * |T|).
- Accuracy: Class A
- Cable Length: 0 m
- Cable Temperature, Max: 0 °C
- Cable Temperature, Min: 0 °C
- Enclosure Ratings: IP65
- Height: 0 mm
- Specifications
- Features
- Downloads
| Part Number | AC1904 |
| Brand | Dwyer |
| Cable Length | 0 m (0.00 ft) |
| Series | AC19XX |
| Accuracy | Class A |
| Cable Temperature, Max | 0 °C (32 °F) |
| Cable Temperature, Min | 0 °C (32 °F) |
| Enclosure Ratings | IP65 |
| Height | 0 mm (0.000 in) |
| Housing Material | 316 Stainless Steel |
| Length | 50 mm (1.97 in) |
| Measurement Type | Temperature |
| Probe Style | Cable Interchangeable Probe |
| Sensor Type | Pt100 |
| Temperature Measurement Range | -50 to 105 °C (-58 to 221 °F) |
| Weight | 0.044 lb |
| Width | 6 mm (0.236 in) |
| Country of Origin | Italy |
- Accuracy: Class A
- Cable Length: 0 m
- Cable Temperature, Max: 0 °C
- Cable Temperature, Min: 0 °C
- Enclosure Ratings: IP65
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer ILA20 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer ILA20 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer ILA10 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer ILA10 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer I2-2A062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-2A062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-25062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-25062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-21042 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-21042 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-26062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-26062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-21062 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-21062 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-1A042 | Immersion Temperature Probe | ± 0.36 °F
Dwyer I2-1A042 | Immersion Temperature Probe | ± 0.36 °F