Dwyer Instruments 2716-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output
The 2700 is an excellent investment because of the Model 2716-WP Current to Pressure Transducer's affordable initial cost, minimal air use, and dependable performance. A variable current signal is converted by the device to a proportionate pneumatic output. Plumbing can be done in a variety of ways because it includes input and output ports on both the front and back. The unit can be mounted both indoors and outdoors thanks to the NEMA 4X casing, although it is not vibration resistant. It is authorized for intrinsically safe operation by the FM and CSA. The 2700 is intended for panel or remote mounting. In essential applications, an inbuilt volume booster increases control speed by offering a high flow capacity. Additional advantages include the convenience of field calibration through external zero and span adjustments.

Free UAE shipping available
- Specifications
- Features
- Downloads
Air Consumption | 0.03 scfm (.01 l/s) at midrange typical |
Air Supply | Min: 5 psig (0.3 bar) above max output Max: 100 psig (6.9 bar) |
Approvals | CE, CSA, FM |
Connection | Electrical: 1/2" female NPT |
Connection | Pressure: 1/4" female NPT |
Enclosure Rating | NEMA 4X (IP66) and intrinsically safe |
Enclosure | Chromate-treated aluminum with epoxy paint |
Hysteresis | <0.5% of span |
Input signal | 4-20 mA |
Linearity | <+/-0.5% of span |
Maximum operating temperature | -20 to 150°F (-29 to 66°C) |
Output | 6-30 psig (0.4-2.1 bar) |
Output | Capacity: 4.5 scfm (2.1 l/s) at 25 psig (1.7 bar) supply; 12.0 scfm (5.7 l/s) at 100 psig (6.9 bar) supply |
Power | Loop powered |
Rating | CSA: Class I, division 2, groups C and D; Class II, groups E, F and G; Class III |
Rating | FM: Class I, II, III, division 1, groups C, D, E, F and G; Class I, division 2, groups A, B, C and D; Class II and III, division 2, groups F and G |
Repeatability | <0.5% of span |
Sensitivity | Supply Pressure: Series 2700: <0.1% of span per 1.0 psig (0.1 bar) |
Weight | 1.3 lb (0.59 kg) |
- NEMA 4X protective housing.
- Approved by FM and CSA for intrinsic safety.
- Insensitive to location and vibration (2700).
- Front and rear input/output ports (2700).
- Insensitive to location and vibration (2800).
- Front and rear input/output ports (2800).
Related Products

Dwyer Instruments IP-44 | Current to pressure transducer | 4-20 mA input | 6-30 psi (40-200 kPa) output

Dwyer Instruments IP-44 | Current to pressure transducer | 4-20 mA input | 6-30 psi (40-200 kPa) output

Dwyer Instruments IP-43 | Current to pressure transducer | 4-20 mA input | 3-27 psi (20-185 kPa) output

Dwyer Instruments IP-43 | Current to pressure transducer | 4-20 mA input | 3-27 psi (20-185 kPa) output

Dwyer Instruments IP-42 | Current to pressure transducer | 4-20 mA input | 3-15 psi (20-100 kPa) output

Dwyer Instruments IP-42 | Current to pressure transducer | 4-20 mA input | 3-15 psi (20-100 kPa) output

Dwyer Instruments 2816-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2816-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2813-WP | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output

Dwyer Instruments 2813-WP | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output

Dwyer Instruments 2916-E | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2916-E | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2913-E | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output

Dwyer Instruments 2913-E | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output