Dwyer Instruments 2916-E | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output
In the riskiest settings, the Model 2916-E Current to Pressure Transducer provides dependable, excellent performance for even the most demanding applications. Its FM and CSA-approved NEMA 4X housing is built for intrinsic safety and explosion-proof performance. This device has sophisticated circuitry with electronic feedback control for excellent vibration prevention and extremely precise output. Field calibration is quick and simple with the 2900's readily accessible zero and span adjustments and lack of position sensitivity. This type features input and output ports on both the front and back for convenience of installation. Furthermore, the 2900 is not sensitive to vibration, which makes it perfect for field mounting on a valve. The unit's small size and these characteristics make installation and setup easier.

Free UAE shipping available
- Specifications
- Features
- Downloads
Accuracy | +/-0.1% of span |
Air Consumption | 0.05 scfm (0.02 l/s) at midrange typical |
Air Supply | Min: 5 psig (0.3 bar) above max output Max: 100 psig (6.9 bar) |
Approvals | CE, CSA, FM |
Connection | Electrical: 1/2" female NPT |
Connection | Pressure: 1/4" female NPT |
Deadband | 0.02% of span |
Enclosure Rating | Weatherproof NEMA 4X (IP66), explosion-proof and intrinsically safe |
Enclosure | Chromate-treated aluminum with epoxy paint |
Hysteresis | +/-0.1% of span |
Input signal | 4-20 mA |
Maximum operating temperature | 40 to 160°F (-40 to 71°C) |
Output | 6-30 psig (0.4-2.1 bar) |
Output | Capacity: 4.5 scfm (2.1 l/s) at 25 psig (1.7 bar) supply; 12.0 scfm (5.7 l/s) at 100 psig (6.9 bar) supply |
Power | Loop powered |
Rating | CSA: Class I, Division 1, Groups B, C and D; Class I, Division 2, Groups A, B, C and D; Class II, Division 1, Groups E, F and G; Class II and III, Division 2, Groups F and G |
Rating | FM: Explosion-proof for Class I, Division 1, Groups B, C and D. T6, Dust Ignition-proof for Class I, Division 1, Groups E, F and G, T6; Intrinsically safe for Class I, II and III, Division 1, Groups C, D, E, F and G, T4 hazardous (classified) locations and intrinsically safe for Class I, Zone 0, Group IIB, T4 hazardous (classified) locations and suitable for Class I, Groups A, B, C, D, T4 and Class II and III, Division 2, Groups F and G, T6 hazardous (classified) locations |
Repeatability | +/-0.1% of span |
Storage Temperature | -40 to 200°F (-40 to 93°C) |
Weight | 1.8 lb (0.82 kg) |
- Developed for Dangerous Conditions.
- Resistant to vibrations.
- Safe from explosions.
- Waterproof and inherently secure.
Related Products

Dwyer Instruments IP-44 | Current to pressure transducer | 4-20 mA input | 6-30 psi (40-200 kPa) output

Dwyer Instruments IP-44 | Current to pressure transducer | 4-20 mA input | 6-30 psi (40-200 kPa) output

Dwyer Instruments IP-43 | Current to pressure transducer | 4-20 mA input | 3-27 psi (20-185 kPa) output

Dwyer Instruments IP-43 | Current to pressure transducer | 4-20 mA input | 3-27 psi (20-185 kPa) output

Dwyer Instruments IP-42 | Current to pressure transducer | 4-20 mA input | 3-15 psi (20-100 kPa) output

Dwyer Instruments IP-42 | Current to pressure transducer | 4-20 mA input | 3-15 psi (20-100 kPa) output

Dwyer Instruments 2816-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2816-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2813-WP | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output

Dwyer Instruments 2813-WP | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output

Dwyer Instruments 2716-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2716-WP | Current to pressure transducer | 4-20 mA input | 6-30 psig (0.4-2.1 bar) output

Dwyer Instruments 2913-E | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output

Dwyer Instruments 2913-E | Current to pressure transducer | 4-20 mA input | 3-15 psig (0.2-1.0 bar) output