Client Protection
Dedicated Support
Genuine Products
Dwyer 616KD-LR-B35-BD1 | Low Range Differential Pressure Transmitter | 0-0.5 in w.c., ±1%, 4-20 mA / 0-10 V
The Dwyer 616KD-LR-B35-BD1 is a Series 616KD-LR low range differential pressure transmitter for 0-0.5 in w.c., with ±1% accuracy, barbed process fittings and both 4-20 mA and 0-10 VDC outputs. A single push button calibrates zero and span without extra calibration equipment or a reference pressure source.
- 0-0.5 in w.c. range; maximum pressure 1 psi
- Outputs: 0-10 VDC and 4-20 mA; supply 21.6-33 VAC
- Barbed process fittings; screw terminal electrical connection
- No display; IP20 and NEMA 1
- Operating temperature 0-140 °F; CE
- Specifications
- Features
- Downloads
| Part Number | 616KD-LR-B35-BD1 |
| Brand | Dwyer |
| Range | 0-0.5 in w.c. |
| Output | 0-10 VDC, 4-20 mA |
| Process Connection | Barbed fitting |
| Approvals | CE |
| Accuracy | ±1% |
| Electrical Connection | Screw terminal |
| Net Weight | 0.11 lb |
| Supply Voltage | 21.6-33 VAC |
| Display | No |
| Protection | IP20; NEMA 1 |
| Temperature Range | 0-140 °F |
| Maximum Pressure | 1 psi |
- Many applications are covered by a large assortment of low ranges and accuracy. Cutting down on parts and standardizing the design.
- Easy calibration pushbuttons that save time during installation and maintenance over the course of the service life to establish zero and span.
- Compact, affordable device ideal for OEM applications where value, simplicity, and space are critical.
- outputs of voltage and current simultaneously.
- Metal barbed fittings or compression fittings for metal tubing can be used with an optional 1/4" NPT process connection.
- Plenum-rated devices that adhere to UL Standard 2043.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer RSME-C-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 1 %
Dwyer RSME-C-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 1 %
Dwyer RSME-C-014-SS | Room Status Monitor | -0.5 to 0.5 inH₂O, ± 1 %
Dwyer RSME-C-014-SS | Room Status Monitor | -0.5 to 0.5 inH₂O, ± 1 %
Dwyer RSME-C-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 1 %
Dwyer RSME-C-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 1 %
Dwyer RSME-C-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 1 %
Dwyer RSME-C-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 1 %
Dwyer RSME-C-004-SS | Room Status Monitor | 0 to 1 inH₂O, ± 1 %
Dwyer RSME-C-004-SS | Room Status Monitor | 0 to 1 inH₂O, ± 1 %
Dwyer RSME-B-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSME-B-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %