Skip to product information
Dwyer Instruments CDTC-5N000 | Communicating carbon dioxide transmitter with temperature output | 5000 PPM range and North American housing - generaltechuae

Dwyer Instruments CDTC-5N000 | Communicating carbon dioxide transmitter with temperature output | 5000 PPM range and North American housing

Part Number : CDTC-5N000

The Dwyer CDTC-5N000 is a communicating CO₂ and temperature transmitter with a 0-5000 ppm CO₂ range and Modbus RTU or BACnet MS/TP communication over RS-485. It combines CO₂, temperature and temperature set-point monitoring in a single North American wall-mount housing for building automation and demand-controlled ventilation applications. Genuine stock at General Tech Services LLC, UAE, with free UAE-wide shipping. Request a quote in under a minute - call +971 6 5436933.

Part No. CDTC-5N000

Product Overview

The Dwyer CDTC-5N000 is part of the Series CDTC Communicating Carbon Dioxide Sensors, combining the functions of multiple room sensors in a single compact housing. It measures CO₂ from 0-5000 ppm and temperature while providing a temperature set point and override function.

The CDTC-5N000 uses a North American wall-mount housing and communicates through RS-485 using either Modbus RTU or BACnet MS/TP. The communication protocol can be selected using onboard DIP switches.

A 4-wire connection and daisy-chain capability can help reduce wiring requirements in multi-device installations. The RS-485 MAC address is configured using onboard DIP switches, while additional DIP-switch settings can control access to the setup menu.

Barometric pressure can be programmed to compensate for altitude, supporting accurate CO₂ measurements at different installation elevations.

The CDTC-5N000 does not include an integral display. The CDTC-5N000-LCD provides the corresponding configuration with an integral LCD display.

Key Benefits

  • Measures CO₂ from 0-5000 ppm and room temperature
  • Provides temperature set point and override functionality
  • Modbus RTU or BACnet MS/TP communication over RS-485
  • 4-wire connection with daisy-chain capability
  • Onboard DIP switches for MAC address and protocol selection
  • Programmable barometric pressure for altitude compensation
  • Combines CO₂ and temperature sensing in one wall-mounted device
  • North American wall-mount housing
  • CDTC-5N000-LCD available with an integral LCD display
  • Genuine Dwyer stock with free UAE-wide shipping

Who This Product Is Best For

  • Commercial buildings requiring room CO₂ monitoring
  • Demand-controlled ventilation systems
  • Building management systems using Modbus RTU or BACnet MS/TP
  • HVAC automation and indoor-air monitoring applications
  • Projects requiring CO₂ and temperature measurements from one wall-mounted device
  • Installations using RS-485 daisy-chain communication

How to Specify & Commission It

  1. Confirm the required CO₂ and temperature monitoring functions and select a suitable wall location.
  2. Mount the North American housing on the wall according to the installation instructions.
  3. Connect the power supply and RS-485 communication wiring, using the 4-wire connection and daisy-chain arrangement where required.
  4. Set the RS-485 MAC address using the onboard DIP switches.
  5. Select Modbus RTU or BACnet MS/TP using the appropriate DIP-switch configuration.
  6. Configure the barometric pressure setting for the installation altitude and verify the CO₂ and temperature readings.
  7. Confirm the temperature set point and override operation before integrating the sensor into the building automation system.

Frequently Asked Questions

What does the Dwyer CDTC-5N000 measure?
It measures CO₂ from 0-5000 ppm and temperature, with a temperature set point and override function.

What communication protocols are supported?
The sensor supports Modbus RTU or BACnet MS/TP over RS-485, selectable using onboard DIP switches.

What is the CO₂ accuracy?
The specified CO₂ accuracy is ±40 ppm ±3% of reading.

Does the CDTC-5N000 have a display?
No. The CDTC-5N000 does not include an integral LCD display. The CDTC-5N000-LCD is the corresponding version with an integral LCD.

Can multiple sensors be connected together?
Yes. The sensor supports RS-485 communication with a 4-wire connection and daisy-chain capability.

Can the MAC address be configured?
Yes. The RS-485 MAC address can be set using the onboard DIP switches.

Can barometric pressure be adjusted?
Yes. Barometric pressure can be programmed to compensate for altitude.

What is the difference between the CDTC-5N000 and CDTC-5N000-LCD?
The CDTC-5N000 is supplied without an integral LCD display. The CDTC-5N000-LCD adds an integral LCD while retaining the communicating CO₂ and temperature transmitter functionality.

Is genuine stock available with UAE shipping?
Yes. Genuine Dwyer stock is available from General Tech Services LLC with free UAE-wide shipping. Call +971 6 5436933 for pricing and current availability.

Request a Quote Today

For pricing or to place an order, contact General Tech Services LLC.

Call +971 6 5436933 | www.generaltechshop.ae

 

Availability: low stock
Free UAE shipping available
For pricing, please contact our experts.