Client Protection
Dedicated Support
Genuine Products
Dwyer DMF-41407 | Digital Mass Flow Controller | 0-1 LPM N2, 1/4" Fitting, RS-485
Dwyer DMF-41407: a 0-1 LPM digital mass flow controller, with range stated as nitrogen-equivalent flow at 70°F (21°C) and 760 mm Hg. Across its 0-1 LPM range it programs and regulates gas flow and records the results.
- 1/4" compression fitting; 0-1 LPM full scale
- Totalise from preset flow; stop and preset totals; auto zero balancing circuit limits zero and span drift
- Pair of dry contacts for external devices; RS-485 interface; 0-5 VDC or 0-10 VDC linear output
- Accuracy ±1% FS under reference conditions; 316/416 SS wetted parts, fluoroelastomer O-rings; 500 psig max
- Specifications
- Features
- Downloads
| Part Number | DMF-41407 |
| Brand | Dwyer |
| Flow Range | 0-1 LPM (N2 at 21°C, 760 mm Hg) |
| Process Connection | 1/4" compression |
| Accuracy | ±1% FS (15-25°C, 0.7-4 bar) |
| Repeatability | ±0.15% FS |
| Response Time | 0.6-1.0 s to ±2% of set point |
| Output | 0-5 VDC; 0-10 VDC |
| Interface | RS-485 |
| Max Pressure | 500 psig (34.5 bar) |
| Operating Temperature | 41 to 122°F (5 to 50°C) |
| Power Supply | ±15 VDC, 13.5 W max |
| Wetted Materials | 316 SS, 416 SS, fluoroelastomer O-rings |
| Approvals | CE |
- The Series DMF controllers allow users to program various control functions, including flow set point, totalizer, stop totalizer, totalize from preset flow, stop and preset total, auto zero, and more.
- Designed with straight tube sensors and restrictor flow elements, the controllers ensure laminar gas flow, leading to accurate and repeatable flow rate measurements.
- The Series DMF controllers are unaffected by variations in temperature and pressure, ensuring consistent performance and reliable results across different operating conditions.
- The auto zero feature utilizes an automatic balancing circuit to virtually eliminate drift of zero and span, maintaining accuracy over time without manual intervention.
- Each Series DMF controller is equipped with two dry contact closures, which can be used to operate pumps, valves, or other process equipment, enhancing system integration and control capabilities.
Related Products
Wöhler 9286 | DC 410 FLOW Pressure Differential & Flow Meter | +/-100 hPa, 0.3 to 120 m/s, Standard Set
Wöhler 9286 | DC 410 FLOW Pressure Differential & Flow Meter | +/-100 hPa, 0.3 to 120 m/s, Standard Set
Dwyer GFC-2143 | Gas Mass Flow Controller | 0-200 L/min N2, 3/8" compression
Dwyer GFC-2143 | Gas Mass Flow Controller | 0-200 L/min N2, 3/8" compression
Dwyer GFC-2142 | Gas Mass Flow Controller | 0-100 L/min N2, 3/8" compression
Dwyer GFC-2142 | Gas Mass Flow Controller | 0-100 L/min N2, 3/8" compression
Dwyer GFC-2133 | Gas Mass Flow Controller | 0-50 L/min N2, 1/4" compression
Dwyer GFC-2133 | Gas Mass Flow Controller | 0-50 L/min N2, 1/4" compression
Dwyer GFC-2131 | Gas Mass Flow Controller | 0-30 L/min N2, 1/4" compression
Dwyer GFC-2131 | Gas Mass Flow Controller | 0-30 L/min N2, 1/4" compression
Dwyer GFC-2111 | Gas Mass Flow Controller | 0-15 L/min N2, 1/4" compression
Dwyer GFC-2111 | Gas Mass Flow Controller | 0-15 L/min N2, 1/4" compression
Dwyer GFC-2109 | Gas Mass Flow Controller | 0-5 L/min N2, 1/4" compression
Dwyer GFC-2109 | Gas Mass Flow Controller | 0-5 L/min N2, 1/4" compression
Dwyer GFC-2108 | Gas Mass Flow Controller | 0-2 L/min N2, 1/4" compression
Dwyer GFC-2108 | Gas Mass Flow Controller | 0-2 L/min N2, 1/4" compression