Skip to product information
Dwyer Instruments GSTA-N-D-FC | Nitrogen duct mount transmitter with universal current/voltage outputs | Includes factory calibration certificate - generaltechuae

Dwyer Instruments GSTA-N-D-FC | Nitrogen duct mount transmitter with universal current/voltage outputs | Includes factory calibration certificate

Part Number : GSTA-N-D-FC

The Dwyer GSTA-N-D-FC is a duct-mount nitrogen dioxide transmitter with field-selectable current or voltage outputs and a factory calibration certificate for garage, loading dock and mechanical room monitoring. Genuine stock at General Tech Services LLC, UAE, with free UAE-wide shipping. Request a quote in under a minute - call +971 6 5436933.

Part No. GSTA-N-D-FC

Product Overview

The Dwyer GSTA-N-D-FC is a Series GSTA nitrogen dioxide (NO₂) transmitter designed for monitoring gas concentrations in mechanical rooms, underground parking garages and loading docks. The nitrogen dioxide version is intended for monitoring diesel-engine exhaust and uses a duct-mount configuration for in-duct sampling.

The transmitter provides field-selectable analog outputs including 4-20 mA, 0-5 V, 0-10 V, 1-5 V and 2-10 V, allowing connection to a wide range of building management and ventilation controllers. Internal DIP switches allow the output to be inverted when required.

The GSTA-N-D-FC has a standard 0-10 ppm nitrogen dioxide range and uses an industrial-grade, field-replaceable sensor. Field calibration can be performed using the A-449 remote LCD service display, which also indicates when the sensor reaches the end of its service life and requires replacement.

The -FC suffix indicates that the transmitter is supplied with a factory calibration certificate. The GSTA-N-D provides the corresponding standard configuration without the factory calibration certificate.

Key Benefits

  • Monitors nitrogen dioxide (NO₂) associated with diesel-engine exhaust
  • Industrial-grade field-replaceable sensor
  • Field-selectable current and voltage outputs
  • Supports 4-20 mA, 0-5 V, 0-10 V, 1-5 V and 2-10 V
  • Output can be inverted using internal DIP switches
  • A-449 service display supports setup and field calibration
  • Duct-mount configuration for in-duct gas sampling
  • Factory calibration certificate included
  • Genuine Dwyer Instruments stock with free UAE-wide shipping

Who This Product Is Best For

  • Underground parking garages and loading docks requiring in-duct NO₂ monitoring for ventilation control
  • Mechanical rooms requiring diesel-engine exhaust monitoring
  • BMS integrators standardising on analog current or voltage gas sensing
  • HVAC and ventilation control systems requiring flexible analog signal options
  • System integrators requiring a factory-calibrated duct-mount NO₂ transmitter

How to Specify & Commission It

  1. Confirm that the application requires nitrogen dioxide (NO₂) monitoring and select a suitable duct location.
  2. Install the duct-mount transmitter according to the manufacturer's installation requirements.
  3. Select the required analog output: 4-20 mA, 0-5 V, 0-10 V, 1-5 V or 2-10 V.
  4. Configure the output direction using the internal DIP switches if an inverted signal is required.
  5. Wire the power supply and selected analog output to the building management, ventilation or control system.
  6. Use the A-449 remote LCD service display for field calibration when required, then verify the transmitter reading and controller response.

Frequently Asked Questions

What gas does the GSTA-N-D-FC detect?

The GSTA-N-D-FC detects nitrogen dioxide (NO₂), used for monitoring diesel-engine exhaust.

What is the standard measurement range?

The standard nitrogen dioxide measurement range is 0-10 ppm.

What outputs are available?

The transmitter provides field-selectable 4-20 mA, 0-5 V, 0-10 V, 1-5 V and 2-10 V outputs.

Can the output signal be inverted?

Yes. The output can be inverted using the internal DIP switches.

Does the GSTA-N-D-FC have an integral LCD display?

No. The GSTA-N-D-FC does not have an integral LCD display. The A-449 remote LCD service display is used for setup and field calibration.

Is the GSTA-N-D-FC wall mount or duct mount?

The GSTA-N-D-FC is a duct-mount nitrogen dioxide transmitter designed for in-duct sampling.

Can the sensor be replaced?

Yes. The transmitter uses an industrial-grade field-replaceable sensor.

How is the sensor calibrated?

Field calibration can be performed using the A-449 remote LCD service display. The service display can also indicate when the sensor requires replacement.

What does the -FC suffix mean?

The -FC suffix indicates that the transmitter is supplied with a factory calibration certificate. The electrical and mechanical configuration is otherwise the same as the standard GSTA-N-D model.

Is genuine Dwyer stock available in the UAE?

Yes. Genuine Dwyer Instruments stock is available through General Tech Services LLC with free UAE-wide shipping. Call +971 6 5436933 for pricing and current availability.

Request a Quote Today

For pricing or to place an order, contact General Tech Services LLC.

Call +971 6 5436933 | www.generaltechshop.ae


 

Availability: low stock
Free UAE shipping available
For pricing, please contact our experts.