Client Protection
Dedicated Support
Genuine Products
Dwyer MARK II 40-1-AV-NIST | Molded Plastic Manometer | 0-1.1" w.c. & 0-4200 fpm, NIST Certificate
Dwyer MARK II 40-1-AV-NIST combines a 0-1.1" w.c. / 0-4200 fpm scale and red fluid (0.826 specific gravity) with a NIST calibration certificate. A Pitot tube must be ordered separately.
- Listed with range 0-1.1" w.c. & 0-4200 fpm, red gage fluid (0.826 sp. gr.), NIST calibration certificate included
- Covers above- and below-atmosphere and differential pressure; accuracy ±3% of full scale
- Overpressure traps built in; quick shut-off fittings; meets EU RoHS II (2011/65/EU) requirements
- No Pitot tube in the box; max operating pressure 10 psi (inclined-vertical) or 15 psi (inclined)
- Specifications
- Features
- Downloads
| Part Number | MARK II 40-1-AV-NIST |
| Brand | Dwyer |
| Series | Mark II Molded Plastic Manometers |
| Range | 0-1.1" w.c. & 0-4200 fpm |
| Accuracy | ±3% FS |
| Maximum Pressure | Inclined/vertical: 10 psi; inclined: 15 psi |
| Approvals | RoHS II (2011/65/EU) |
| Pitot Tube | Required, sold separately |
| Gage Fluid | Red |
| Specific Gravity | 0.826 |
| Calibration | NIST calibration certificate |
- Almost unbreakable thick white styrene-acrylonitrile housing.
- An overflow tank (Model 25) or float-operated overflow traps (Model 40) can handle moderate overpressures.
- Able can be fixed in any upright position.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer 3000MRS-100MM | Photohelic® Switch/Gage | 0 inH₂O to 100 mmHg, ± 2 %
Dwyer 3000MRS-100MM | Photohelic® Switch/Gage | 0 inH₂O to 100 mmHg, ± 2 %
Dwyer 3000MRS-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MRS-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MRS-250PA | Photohelic® Switch/Gage | 0 inH₂O to 250 Pa, ± 2 %
Dwyer 3000MRS-250PA | Photohelic® Switch/Gage | 0 inH₂O to 250 Pa, ± 2 %
Dwyer 3000MRS-3KPA | Photohelic® Switch/Gage | 0 inH₂O to 3 kPa, ± 2 %
Dwyer 3000MRS-3KPA | Photohelic® Switch/Gage | 0 inH₂O to 3 kPa, ± 2 %
Dwyer 3000MRS-10MM | Photohelic® Switch/Gage | 0 inH₂O to 10 mmHg, ± 3 %
Dwyer 3000MRS-10MM | Photohelic® Switch/Gage | 0 inH₂O to 10 mmHg, ± 3 %
Dwyer 3000MRS-125PA | Photohelic® Switch/Gage | 0 inH₂O to 125 Pa, ± 3 %
Dwyer 3000MRS-125PA | Photohelic® Switch/Gage | 0 inH₂O to 125 Pa, ± 3 %
Dwyer 3000MR-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MR-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MRS-25MM | Photohelic® Switch/Gage | 0 inH₂O to 25 mmHg, ± 2 %
Dwyer 3000MRS-25MM | Photohelic® Switch/Gage | 0 inH₂O to 25 mmHg, ± 2 %