Client Protection
Dedicated Support
Genuine Products
Dwyer PAFS-1009 | Averaging Flow Sensor | 19-13/32" (49.29 cm) insertion
With a 19-13/32" (49.29 cm) insertion length, the Dwyer PAFS-1009 averaging flow sensor measures velocity pressure in the inlet section of variable air volume and fan terminal units. Beyond terminal units, the PAFS-1009 can detect differential pressure at various locations in main or branch ducts.
- PAFS-1009 insertion length: 19-13/32" (49.29 cm)
- Polycarbonate construction; wetted parts ABS/polycarbonate (UL94-5V) on the PAFS-1009
- Mounts via an integral flange with gasket; PAFS-1009 connects to 1/4" (6 mm) ID, 3/8" (10 mm) OD tubing
- PAFS-1009 operating temperature 40 to 120°F (4 to 49°C), storage -40 to 140°F (-40 to 60°C)
- Weight 1 oz (28 g); PAFS-1009 meets EU RoHS II (2011/65/EU) technical requirements
- Specifications
- Features
- Downloads
| Part Number | PAFS-1009 |
| Brand | Dwyer |
| Product Type | Averaging flow sensor |
| Series | PAFS-1000 |
| Insertion Length | 19-13/32" (49.29 cm) |
| Material | Polycarbonate |
| Wetted Material | ABS/polycarbonate (UL94-5V) |
| Process Connection | 1/4" (6 mm) ID, 3/8" (10 mm) OD tubing |
| Port Size | 1/4" |
| Mounting | Integral flange with gasket |
| Operating Temperature | 40 to 120°F (4 to 49°C) |
| Storage Temperature | -40 to 140°F (-40 to 60°C) |
| Weight | 1 oz (28 g) |
| Approvals | RoHS II (EU Directive 2011/65/EU) |
- You can use a simple mounting flange with rectangular or round ducts.
- Total pressure is sensed by the "H" port, and static pressure is sensed by the "L" port.
- The differential, also known as velocity pressure, exists between these signals.
- In order to fit box size diameters of 4 to 16" (10.16 to 40.64 cm), up to four sensing points and lengths of 3-5/32to 9-29/32" (8.02 to 25.62 cm) are available.
Related Products
ifm SBY332, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 15 L/min Max
ifm SBY332, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 15 L/min Max
ifm SBG233, SBG Series Flow Meter for Coolants, Glycol Solutions, Water, 0.5 l/min Min, 25 L/min Max
ifm SBG233, SBG Series Flow Meter for Coolants, Glycol Solutions, Water, 0.5 l/min Min, 25 L/min Max
ifm SV4051, SV4 Series Vortex Flow Meter Flow Meter for Water, 0.9 l/min Min, 15 L/min Max
ifm SV4051, SV4 Series Vortex Flow Meter Flow Meter for Water, 0.9 l/min Min, 15 L/min Max
ifm SBN346, SBN Series Flow Sensor for Coolants, Glycol Solutions, Water, 1.32 gpm Min, 26.4 gpm Max
ifm SBN346, SBN Series Flow Sensor for Coolants, Glycol Solutions, Water, 1.32 gpm Min, 26.4 gpm Max
ifm SB5242, SB5 Series Flow Meter for Liquid, 0.6 l/min Min, 15 L/min Max
ifm SB5242, SB5 Series Flow Meter for Liquid, 0.6 l/min Min, 15 L/min Max
ifm SBY333, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 25 L/min Max
ifm SBY333, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 25 L/min Max
ifm SB2246, SB2 Series Flow Meter for Liquid, 2 l/min Min, 100 L/min Max
ifm SB2246, SB2 Series Flow Meter for Liquid, 2 l/min Min, 100 L/min Max
ifm SA4104, SA4 Series Flow Sensor for Gas, Liquid, 0 m/s Min, 200 m/s Max
ifm SA4104, SA4 Series Flow Sensor for Gas, Liquid, 0 m/s Min, 200 m/s Max