Dwyer PAFS-1011 is an averaging flow sensor with an insertion length of 23-29/32" (60.72 cm), made for measuring velocity pressure at the inlet of VAV and fan terminal units. The PAFS-1011 can also sense differential pressure at points in main or branch duct runs.
- PAFS-1011 insertion length: 23-29/32" (60.72 cm)
- Polycarbonate construction; wetted parts ABS/polycarbonate (UL94-5V) on the PAFS-1011
- Mounts via an integral flange with gasket; PAFS-1011 connects to 1/4" (6 mm) ID, 3/8" (10 mm) OD tubing
- PAFS-1011 operating temperature 40 to 120°F (4 to 49°C), storage -40 to 140°F (-40 to 60°C)
- Weight 1 oz (28 g); PAFS-1011 meets EU RoHS II (2011/65/EU) technical requirements
- Specifications
- Features
- Downloads
| Part Number | PAFS-1011 |
| Brand | Dwyer |
| Product Type | Averaging flow sensor |
| Series | PAFS-1000 |
| Insertion Length | 23-29/32" (60.72 cm) |
| Material | Polycarbonate |
| Wetted Material | ABS/polycarbonate (UL94-5V) |
| Process Connection | 1/4" (6 mm) ID, 3/8" (10 mm) OD tubing |
| Port Size | 1/4" |
| Mounting | Integral flange with gasket |
| Operating Temperature | 40 to 120°F (4 to 49°C) |
| Storage Temperature | -40 to 140°F (-40 to 60°C) |
| Weight | 1 oz (28 g) |
| Approvals | RoHS II (EU Directive 2011/65/EU) |
- You can use a simple mounting flange with rectangular or round ducts.
- Total pressure is sensed by the "H" port, and static pressure is sensed by the "L" port.
- The differential, also known as velocity pressure, exists between these signals.
- In order to fit box size diameters of 4 to 16" (10.16 to 40.64 cm), up to four sensing points and lengths of 3-5/32to 9-29/32" (8.02 to 25.62 cm) are available.
Related Products
ifm SBY332, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 15 L/min Max
ifm SBY332, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 15 L/min Max
ifm SBG233, SBG Series Flow Meter for Coolants, Glycol Solutions, Water, 0.5 l/min Min, 25 L/min Max
ifm SBG233, SBG Series Flow Meter for Coolants, Glycol Solutions, Water, 0.5 l/min Min, 25 L/min Max
ifm SV4051, SV4 Series Vortex Flow Meter Flow Meter for Water, 0.9 l/min Min, 15 L/min Max
ifm SV4051, SV4 Series Vortex Flow Meter Flow Meter for Water, 0.9 l/min Min, 15 L/min Max
ifm SBN346, SBN Series Flow Sensor for Coolants, Glycol Solutions, Water, 1.32 gpm Min, 26.4 gpm Max
ifm SBN346, SBN Series Flow Sensor for Coolants, Glycol Solutions, Water, 1.32 gpm Min, 26.4 gpm Max
ifm SB5242, SB5 Series Flow Meter for Liquid, 0.6 l/min Min, 15 L/min Max
ifm SB5242, SB5 Series Flow Meter for Liquid, 0.6 l/min Min, 15 L/min Max
ifm SBY333, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 25 L/min Max
ifm SBY333, SBY Series Flow Sensor for Coolants, Glycol Solutions, Water, 1 l/min Min, 25 L/min Max
ifm SB2246, SB2 Series Flow Meter for Liquid, 2 l/min Min, 100 L/min Max
ifm SB2246, SB2 Series Flow Meter for Liquid, 2 l/min Min, 100 L/min Max
ifm SA4104, SA4 Series Flow Sensor for Gas, Liquid, 0 m/s Min, 200 m/s Max
ifm SA4104, SA4 Series Flow Sensor for Gas, Liquid, 0 m/s Min, 200 m/s Max