Client Protection
Dedicated Support
Genuine Products
Dwyer TUF-500-BN | BTU Meter | Flow: 66 (250), GB9119 flange, 2" DN50 PN16
The Dwyer TUF-500-BN is a BTU meter with range Flow: 66 (250), connection GB9119 flange, 2" DN50 PN16 and display 8-digit LCD. Dwyer lists with no moving components and a local parameter display, maintenance expenses are reduced., data transmission with serial communication output standard that is seamless. and combined flow and temperature monitoring in one device eliminates the need for separate ones. among its features.
- Accuracy: BTU: EN1434/CJ128 Class 2 Flow: ±(2+(0.02 Qp/Q))% Temperature: ±0.1°C (±0.18°F)
- Approvals: CE, RoHS
- Communication: BACnet® MSTP
- Connection: GB9119 flange, 2" DN50 PN16
- Connection: Electrical: 3' (0.91 m) 4x0.2 mm² cable with terminal block
- Display: 8-digit LCD
- Enclosure Material: Plastic
- Enclosure Rating: IP65
- Specifications
- Features
- Downloads
| Part Number | TUF-500-BN |
| Type | Tenant Ultrasonic BTU Flowmeter |
| Communication | BACnet® MSTP |
| Display | 8-digit LCD |
| Enclosure Rating | IP65 |
| Permanent (Rated) Flow Rate | 15 m³/h |
| Pipe Size | DN50 |
| Accuracy | BTU: EN1434/CJ128 Class 2 Flow: ±(2+(0.02 Qp/Q))% Temperature: ±0.1 °C (±0.18 °F) |
| Approvals | CE, RoHS |
| Connection | GB9119 flange, 2" DN50 PN16 |
| Connection | Electrical: 3' (0.91 m) 4x0.2 mm² cable with terminal block |
| Enclosure Material | Plastic |
| Flow Direction | Unidirectional |
| Humidity | Limit: <93% |
| Manufacturer | Dwyer Instruments |
| Material | Wetted: Brass and 316L stainless steel |
| Maximum Operating Pressure | 362 psi (25 bar) |
| Maximum Operating Temperature | Ambient: 41 to 131 °F (5 to 55 °C) Process: 36 to 203 °F (2 to 95 °C) |
| Mounting | Horizontal or vertical (≥45° from horizontal on horizontal runs) |
| Power Consumption | 1 W |
| Power Supply | 24 VAC/VDC, or 3.6 V ER26500 lithium battery (user-supplied backup) |
| Pressure Drop | 1.5 psi (10 kPa) maximum |
| Repeatability | Flowmeter: 1% |
| Weight | 33 lb (15 kg) |
| Range | Flow: 66 (250) |
- With no moving components and a local parameter display, maintenance expenses are reduced.
- Data transmission with serial communication output standard that is seamless.
- Combined flow and temperature monitoring in one device eliminates the need for separate ones.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer TUF-800-MD | BTU Meter | Flow: 176 (667), GB9119 flange, DN80 PN16
Dwyer TUF-800-MD | BTU Meter | Flow: 176 (667), GB9119 flange, DN80 PN16
Dwyer TUF-320-MD | BTU Meter | Flow: 26 (100), 8-digit LCD
Dwyer TUF-320-MD | BTU Meter | Flow: 26 (100), 8-digit LCD
Dwyer TUF-2000-MD | BTU Meter | Flange connection, DN200, 8-digit LCD
Dwyer TUF-2000-MD | BTU Meter | Flange connection, DN200, 8-digit LCD
Dwyer TUF-1500-MD | BTU Meter | Flange connection, DN150, 8-digit LCD
Dwyer TUF-1500-MD | BTU Meter | Flange connection, DN150, 8-digit LCD
Dwyer TUF-150-MD | BTU Meter | Flow: 6.6 (25), 8-digit LCD
Dwyer TUF-150-MD | BTU Meter | Flow: 6.6 (25), 8-digit LCD
Dwyer TUF-1250-MD | BTU Meter | Flow: 440 (1667), GB9119 flange, 5" DN125 PN16
Dwyer TUF-1250-MD | BTU Meter | Flow: 440 (1667), GB9119 flange, 5" DN125 PN16
Dwyer TUF-1000-MD | Ultrasonic BTU Meter | DN100, 60 m³/h, Modbus
Dwyer TUF-1000-MD | Ultrasonic BTU Meter | DN100, 60 m³/h, Modbus
Dwyer TUF-650-MD | BTU Meter | Flow: 110 (417), GB9119 flange, DN65 PN16