Client Protection
Dedicated Support
Dwyer PMT2-03-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
The Dwyer PMT2-03-A-U2 is a particulate transmitter: 3" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections.
The Dwyer Series PMT2 Particulate Transmitter is designed to measure particulate emission levels from dust collector discharge. Using DC coupled electrostatic induction sensing technology, the transmitter monitors a pA current generated as particulate passes near the probe and outputs a 4-20 mA signal that varies with the particulate level. The series supports air and compatible gases containing any type of conductive or non-conductive particulate.
- Accuracy: ± 5 %
- Averaging Time: 1 to 360 s (10 selectable options)
- Compliance Note: UL Listed Intrinsically Safe for Class I, Groups C and D; Class II, Groups E, F and G; Class III; Class I Zone 0 AEx ia IIB T4 Ga; Class I Zone 0 Ex ia IIB T4 Ga
- Detection Range: 5 to 5000 pA
- Electrical Connection: Two 1/2˝ NPT Female
- Electrical Output: 4 to 20 mA
- Specifications
- Features
- Downloads
| Part Number | PMT2-03-A-U2 |
| Brand | Dwyer |
| Accuracy | ± 5 % |
| Series | PMT2 |
| Averaging Time | 1 to 360 s (10 selectable options) |
| Compliance Note | UL Listed Intrinsically Safe for Class I, Groups C and D; Class II, Groups E, F and G; Class III; Class I Zone 0 AEx ia IIB T4 Ga; Class I Zone 0 Ex ia IIB T4 Ga |
| Detection Range | 5 to 5000 pA |
| Electrical Connection | Two 1/2˝ NPT Female |
| Electrical Output | 4 to 20 mA |
| Enclosure Ratings | IP66, UL Type 4 |
| Materials | Aluminum |
| Operating Temperature, Max | 145 °F |
| Operating Temperature, Min | -40 °F |
| Particulate Size, Max | 0.3 µm and higher |
| Probe Length | 3 in |
| Process Connection Size | 3/4 in |
| Process Connection Type | NPT Male |
| Process Temperature, Max | 248 °F |
| Process Temperature, Min | -40 °F |
| Proof Pressure | Up to 30 psi |
| Supply Power Type | DC |
| Supply Voltage | 12 to 28 Vdc |
| Terminal Block | Removable (16 to 20 AWG Wire) |
| Country of Origin | United States |
- Accuracy: ± 5 %
- Averaging Time: 1 to 360 s (10 selectable options)
- Compliance Note: UL Listed Intrinsically Safe for Class I, Groups C and D; Class II, Groups E, F and G; Class III; Class I Zone 0 AEx ia IIB T4 Ga; Class I Zone 0 Ex ia IIB T4 Ga
- Detection Range: 5 to 5000 pA
- Electrical Connection: Two 1/2˝ NPT Female
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer PMT2-36-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-36-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-05-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-05-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-30-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-30-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-10-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-10-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-20-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-20-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-15-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMT2-15-A-U2 | Particulate Transmitter | 5 to 5000 pA, ± 5 %, 4 to 20 mA
Dwyer PMI-10DA-N-LCD | Particulate Transmitter | PM10 duct mount, 4-20 mA/0-10 V, LCD
Dwyer PMI-10DA-N-LCD | Particulate Transmitter | PM10 duct mount, 4-20 mA/0-10 V, LCD
Dwyer PMI-2.5DA-N-LCD | Particulate Transmitter | PM2.5 duct mount, 4-20 mA/0-10 V, LCD
Dwyer PMI-2.5DA-N-LCD | Particulate Transmitter | PM2.5 duct mount, 4-20 mA/0-10 V, LCD