Client Protection
Dedicated Support
Dwyer S2-1A | Surface Mount Temperature Sensor | ± 0.5 °C
The Dwyer S2-1A is a surface mount temperature sensor: 10K Type III thermistor.
The Dwyer Series S2 Surface Mount Temperature Sensor provides a cost-effective and reliable solution for surface contact temperature measurement. The series is designed for conditioned water pipes, low pressure steam lines, or refrigerant lines. It serves as a low-profile sensor that can be taped or strapped to the outside of a pipe, making it suitable for applications where immersion wells are not feasible. Documented uses include heating or cooling loop line temperature monitoring and HVAC systems.
- Accuracy: ± 0.5 °C
- Accuracy Detail: ±0.5°C interchangeable @ 77°F (25°C)
- Cable Length: 2 ft
- Mounting Orientation: Surface Mount
- Operating Temperature, Max: 250 °F
- Operating Temperature, Min: -40 °F
- Specifications
- Features
- Downloads
| Part Number | S2-1A |
| Brand | Dwyer |
| Cable Length | 2 ft |
| Series | S2 |
| Accuracy | ± 0.5 °C |
| Accuracy Detail | ±0.5 °C interchangeable @ 77 °F (25 °C) |
| Mounting Orientation | Surface Mount |
| Operating Temperature, Max | 250 °F |
| Operating Temperature, Min | -40 °F |
| Probe Diameter | 0.25 in |
| Probe Length | 1 in |
| Sheath Material | 304 Stainless Steel |
| Temperature Sensor Type | 10 kΩ NTC Type III Thermistor |
| Country of Origin | China |
- Accuracy: ± 0.5 °C
- Accuracy Detail: ±0.5°C interchangeable @ 77°F (25°C)
- Cable Length: 2 ft
- Mounting Orientation: Surface Mount
- Operating Temperature, Max: 250 °F
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer ILA20 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer ILA20 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer ILA10 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer ILA10 | In-Line Infrared Temperature Sensor | 32 to 932°F, ± 1 %
Dwyer I2-2A062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-2A062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-25062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-25062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-21042 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-21042 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-26062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-26062 | General Purpose Immersion Temperature Sensor | ± 0.36 °F
Dwyer I2-21062 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-21062 | General Purpose Immersion Temperature Sensor | ± 0.6 %
Dwyer I2-1A042 | Immersion Temperature Probe | ± 0.36 °F
Dwyer I2-1A042 | Immersion Temperature Probe | ± 0.36 °F