FEMA DWAM/DWAMV | Steam and Hot-Water Pressure Monitors | PED 2014/68/EU, burst >= 100 bar, SIL 2
FEMA DWAM and DWAMV pressure monitors handle maximum-pressure monitoring in steam and hot-water systems to TRBS, DIN EN 12828, DIN EN 12952-11 and DIN EN 12953-9. The special-construction switch has a self-monitoring pressure sensor built to the Pressure Equipment Directive 2014/68/EU, with a TÜV-verified bursting pressure of at least 100 bar. DWAM types have no differential adjustment; DWAMV types do.
Key features
- Self-monitoring sensor of special construction
- Calibrated so switching occurs at the set point under rising pressure
- Usable as pressure monitor or maximum-pressure limiter
- Rugged housing of seawater-resistant die-cast aluminium
- TÜV-DW-15-132 approval and SIL 2 to IEC 61508-2
- Specifications
| Series code | DWAM-DWAMV-SERIES |
| Brand | FEMA |
| Series | DWAM (fixed differential) / DWAMV (adjustable) |
| Application | Steam and hot-water systems |
| Pressure Type | Overpressure (relative) |
| Minimum Ambient Temperature | -20 °C |
| Process Connection | G1/4 internal, G1/2 external |
| Bursting Pressure | ≥ 100 bar (TÜV verified) |
| Directive | PED 2014/68/EU |
| Approvals | TÜV-DW-15-132; SIL 2 (IEC 61508-2) |
Related Products
FEMA Ex-DGM | ATEX Gas Pressure Monitors | DIN EN 1854, ATEX, SIL 2
FEMA Ex-DGM | ATEX Gas Pressure Monitors | DIN EN 1854, ATEX, SIL 2
FEMA FD16-327 | LPG Maximum Pressure Limiter, Internal Interlock | 3-16 bar, Ex-i, internal interlock
FEMA FD16-327 | LPG Maximum Pressure Limiter, Internal Interlock | 3-16 bar, Ex-i, internal interlock
FEMA Ex-DNS/Ex-VNS | ATEX Stainless Pressure and Vacuum Switches | 1.4571 sensor, ATEX + IECEx
FEMA Ex-DNS/Ex-VNS | ATEX Stainless Pressure and Vacuum Switches | 1.4571 sensor, ATEX + IECEx
FEMA FD16-326 | LPG Maximum Pressure Limiter, External Interlock | 3-16 bar, Ex-i, external interlock
FEMA FD16-326 | LPG Maximum Pressure Limiter, External Interlock | 3-16 bar, Ex-i, external interlock
FEMA Ex-DCM/Ex-DNM | ATEX Overpressure Switches | ATEX + IECEx, -20 to 60 °C, SIL 2
FEMA Ex-DCM/Ex-DNM | ATEX Overpressure Switches | ATEX + IECEx, -20 to 60 °C, SIL 2
FEMA SDBAM | Steam and Hot-Water Pressure Limiters | Internal interlock, -20 to 70 °C, SIL 2
FEMA SDBAM | Steam and Hot-Water Pressure Limiters | Internal interlock, -20 to 70 °C, SIL 2
FEMA Ex-VCM/Ex-VNM | ATEX Negative Pressure Switches | ATEX + IECEx, SIL 2
FEMA Ex-VCM/Ex-VNM | ATEX Negative Pressure Switches | ATEX + IECEx, SIL 2
FEMA Ex-DDCM | ATEX Differential Pressure Switches | ATEX + IECEx, G1/4, SIL 2
FEMA Ex-DDCM | ATEX Differential Pressure Switches | ATEX + IECEx, G1/4, SIL 2