FLUIDWELL D016 DIN Panel mount - Flow rate Indicator / Totalizer | with linearization and pulse signal output | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
The panel mount indicator/transmitter D016 uses linearization to show the cumulative total, actual flow rate, and total flow rate. Two CLEAR button presses will return the sum to zero. However, it is not possible to reset the eleven-digit cumulative total to zero. Eight linearization points with their corresponding frequencies or values can be specified in addition to the average K-Factor or Span. In any flowrange, the unit will interpolate between these points to significantly improve accuracy. Applications with extremely low frequencies are also supported. Both the pulse output and the visible data are impacted by this linearization.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Flowmeter Inputs Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
Power Supply | Basic: 8 - 30V DC (no real sensor supply). Long life Lithium battery. 24V AC/DC + sensor supply. 115 " 230V AC + sensor supply. Sensor Supply 1.2 / 3V DC. 8.2, 12 & 24V DC. |
- shows the total, accumulated total, and flow rate.
- The flowcurve was linearized in eight points using interpolation.
- Large flow rate or total digits measuring 17 mm (0.67").
- Volumetric or mass engineering units are selectable on the screen.
- the capacity to handle any kind of pulse flowmeter signal.
- Run totals and settings are automatically backed up.
- From -40°C to +80°C (40°F to 176°F) is the ambient temperature.
- Backlighting with LEDs available.
- Simple setup with readable alphanumeric text.
- Aluminum DIN front panel measuring 144 x 72 mm (5.67" x 2.83") in accordance with IEC 61554 / DIN 43700.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT