FLUIDWELL F013 Intrinsically safe - Flow rate Monitor / Totalizer | with one high / low alarm output | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
With its continuous flow rate monitoring capability, the F013 is a multipurpose flow rate indicator and totalizer. Its alarm values are for one high flow rate and one low flow rate. An alert ignore function can be configured to tolerate an inaccurate flow rate for a predetermined amount of time, if desired. Flow rate, total, accumulated total, alarm values, and alarm messages are all displayed on the display. From a wide assortment, on-screen engineering units are simple to configure.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Signal Inputs Flowmeter Inputs Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. (0)4 " 20mA. |
Power Supply | Long life Lithium battery. 4 " 20mA, input Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply : 3.2, 8.2, 12, 24V DC. |
- Flow rate, total, accumulated total, alarm values, and alarm messages are all displayed on the display.
- Large digit selection available for total or flow rate.
- clearly displays the alarm messages.
- In the event of a flow rate alert, the red flashing LED illumination has adjustable intensity.
- Monitoring of flow rate: low and high flow rate alarms are two possible alarm settings.
- The operator can alter the alarm values, or they can be password-protected.
- For high, low, or both combined flow rate alarms, there is just one alarm output.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct technical units for total and flow rate.
- In accordance with ATEX, IECEx, FM, and CSA C-US, intrinsic safety.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT