The actual flow rate, total, and cumulative total are shown via the F014 local indicator/transmitter. To retransmit the count on the display, a scaled pulse corresponding to the cumulative total is produced. Two presses of the CLEAR button will return the total to zero. Like the running total, the accumulated total can register up to 11 digits and is stored up in EEPROM memory once every minute.
From a wide assortment, on-screen engineering units are simple to configure.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Flowmeter Inputs Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. (0)4 " 20mA. |
Power Supply | Long life Lithium battery. 4 " 20mA, input Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply : 3.2, 8.2, 12, 24V DC. |
- simultaneously shows the total, the flow rate, and any additional accumulated total.
- Large digit selection available for total or flow rate.
- Engineering units for flow rate that can be chosen on-screen include mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P, or no unit at all. /sec, /min, /hour, or /day are the time units for flow rate.
- Engineering units for the total that can be chosen on the screen include kg, lb, bbl, GAL, USGAL, ml, L, and m³.
- Scaled pulse output with the sum accumulated reflected in it.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct technical units for total and flow rate.
- Backlight made of LEDs with intensity control.
- In accordance with ATEX, IECEx, FM, and CSA C-US, intrinsic safety.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT