Client Protection
Dedicated Support
Genuine Products
Fluidwell F016 | Intrinsically Safe Flow rate Indicator / Totalizer | with linearization and pulse output, ambient -40°C to +70°C
The F016 is a local flow rate indicator / totalizer which displays the actual flow rate, total and accumulated total. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. Typical use: Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range is required.
Key features
- Displays total and flow rate simultaneously and additional accumulated total.
- Large digit selection for flow rate or total.
- Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
- Eight point linearization of the flow curve - with interpolation.
- Scaled pulse output reflecting the accumulated total.
- Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
- Total - resettable: seven 17mm (0.67") digits.
- Specifications
- Features
- Downloads
| Part Number | F016 |
| Brand | Fluidwell |
| Product Type | Flow rate Indicator / Totalizer |
| Enclosure / Area | Safe area / Intrinsically safe |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
| Supply - Power Supply | Long life Lithium battery.; 8 – 24V AC/DC.; 115 – 230V AC.; Basic: 8 - 30V DC. |
| Supply - Sensor Supply | 3.2, 8.2, 12, 24V DC. |
| Signal Outputs - Pulse Outputs | Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons). Max. frequency: 500Hz. Adjustable pulse length from 1 msec. to 10 seconds.; Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay. |
| Hazardous Area - Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da; IECEx: Gas: Ex ia IIC T4 Ga Dust: Ex ia IIIC T200 100 °C Da; CSA: I.S. Class I/II/III, Div 1, Grp A...G, T4 Class I, Zone 0, AEx ia IIC T4 Ga Note: Extended aluminum enclosures not available with CSA/FM approval. |
- simultaneously shows the total, the flow rate, and any additional accumulated total.
- Large digit selection available for total or flow rate.
- Engineering units for flow rate that can be chosen on-screen include mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P, or no unit at all. /sec, /min, /hour, or /day are the time units for flow rate.
- Engineering units for the total that can be chosen on the screen include kg, lb, bbl, GAL, USGAL, ml, L, and m³.
- The flow curve was linearized to eight points using interpolation.
- Scaled pulse output with the sum accumulated reflected in it.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct technical units for total and flow rate.
- Backlight made of LEDs with intensity control.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C