FLUIDWELL F118 Intrinsically safe - Flow rate Monitor / Totalizer | with linearization | high / low alarms | analog and pulse outputs | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
The F118 is a multifunctional transmitter, totalizer, and flow rate indicator that can accurately linearize the flowmeter signal. Ten linearization points with their frequencies or values can be specified in addition to the average K-Factor or Span. Even for very low frequency applications, the device will interpolate between these locations, significantly improving accuracy in any flow range. Additionally, a capability for continuous flow rate monitoring is included, complete with up to three alarm outputs and high and low flow rate alarm values.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Signal Inputs Flowmeter Inputs Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
Power Supply | Long life Lithium battery. 4 " 20mA Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply : 3.2, 8.2, 12, 24V DC. |
- The flow curve was linearized to ten points using interpolation.
- Monitoring of flow rate: low and high flow rate alarms are two possible alarm settings.
- The operator can alter the alarm values, or they can be password-protected.
- Pulse and analog outputs.
- The linearized flow rate, total, accumulated total, alarm values, alarm messages, and status are all displayed on the display.
- Counting in seven 8mm (0.31") increments.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct engineering units on the display for the total and flow rate.
- Three programmable alarm or scaled pulse outputs are possible.
- clearly displays the alarm messages.
- LED backlighting.
- ATEX and IECEx certified as intrinsically safe. GRP, aluminum, or premium stainless steel enclosure.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT