FLUIDWELL F126-EL | Intrinsically safe - Flow Computer for liquids | with temperature compensation for corrected volume | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
The corrected liquid volume under standard conditions can be computed with the F126-EL flow computer. By measuring the uncorrected volumetric flow and the real line temperature, which is then processed using the thermal expansion coefficient algorithm stored in the flow computer, the corrected volumetric flow is determined. You can provide the appropriate temperature for the reference, such as 15°C, 20°C, or 60°F.
The display indicates the actual line temperature as well as the total, accumulated total, and adjusted flow rate. Nm³ and other on-screen engineering units are readily configurable from a wide range of options.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Flowmeter Inputs Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. Temperature Inputs PT100 - 2 or 3 wire PRTD sensor. |
Power Supply | Long life Lithium battery. 4 " 20mA Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply 3.2, 8.2, 12, 24V DC. |
- use a temperature/expansion relationship to calculate the corrected flow rate, total, and accumulated total.
- shows the line's real temperature.
- An analog signal that is output that shows the flow rate correction.
- simultaneously shows the total, the flow rate, and any additional accumulated total.
- Counting in seven 8mm (0.31") increments.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- Six 17mm (0.67"). temperature digits.
- On the display are engineering units for temperature, flow rate, and total.
- LED backlighting.
- intrinsic safety as defined by IECEx and ATEX.
- Enclosures made of GRP, aluminum, or premium stainless steel.
- EEPROM memory is used for automatic setting and running total backups.
- From -40°C to +80°C (40°F to 176°F) is the ambient temperature.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT