Client Protection
Dedicated Support
Genuine Products
Fluidwell F126-EL | Intrinsically Safe Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
The F126-EL flow computer has been developed to calculate corrected liquid volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow and actual line temperature which is processed with the thermal expansion coefficient algorithm stored in the flow computer. The reference temperature can be defined as desired (e.g. 15°C, 20°C or 60°F). Typical use: Liquid flow measurement in applications where nett flow calculation at base conditions is desired without the influence of thermal product expansion.
Key features
- Calculates compensated flow rate, total and accumulated total based on a temperature/expansion relationship.
- Displays actual line temperature.
- Analog output signal reflecting the corrected flow rate.
- Displays total and flow rate simultaneously and additional accumulated total.
- Flow rate: seven 8mm (0.31") digits.
- Total - resettable: seven 17mm (0.67") digits.
- Accumulated total - not resettable: eleven 8mm (0.31") digits.
- Specifications
- Features
- Downloads
| Part Number | F126-EL |
| Brand | Fluidwell |
| Product Type | Flow Computer for liquids |
| Enclosure / Area | Safe area / Intrinsically safe |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA Loop-powered.; 8 – 24V AC/DC.; 115 – 230V AC.; Basic: 8 - 30V DC. |
| Supply - Sensor Supply | 3.2, 8.2, 12, 24V DC. |
| Signal Outputs - Pulse Outputs | Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons). Max. frequency: 500Hz. Adjustable pulse length from 0.001 sec. to 9.999 seconds.; Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay. |
| Signal Outputs - Analog Outputs | Function: Re-transmitting the compensated flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).; Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output. |
| Hazardous Area - Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIB/IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da; IECEx: Gas: Ex ia IIC/IIB T4 Ga Dust: Ex ia IIIC T200 100 °C Da. |
| Communication | Function: All process data and settings can be read and modified through the communication link. Protocol: Modbus RTU. Interface: RS232 / RS485 2-wire or 4-wire / TTL. |
| Signal Inputs - Temperature Inputs | PT100 - 2 or 3 wire PRTD sensor. |
- use a temperature/expansion relationship to calculate the corrected flow rate, total, and accumulated total.
- shows the line's real temperature.
- An analog signal that is output that shows the flow rate correction.
- simultaneously shows the total, the flow rate, and any additional accumulated total.
- Counting in seven 8mm (0.31") increments.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- Six 17mm (0.67"). temperature digits.
- On the display are engineering units for temperature, flow rate, and total.
- LED backlighting.
- intrinsic safety as defined by IECEx and ATEX.
- Enclosures made of GRP, aluminum, or premium stainless steel.
- EEPROM memory is used for automatic setting and running total backups.
- From -40°C to +80°C (40°F to 176°F) is the ambient temperature.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C