Client Protection
Dedicated Support
Genuine Products
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
The F127 flow computer has been developed to calculate corrected differential liquid volume at normal conditions. This is calculated by measuring the uncorrected volumetric flow and actual line temperature in both the supply and return line. These signals are processed with the thermal expansion coefficient algorithm stored in the flow computer.
Key features
- Displays corrected consumption (flow rate), total and accumulated total.
- Supply line: displays actual temperature and corrected flow rate.
- Return line: displays actual temperature and corrected flow rate.
- Analog output signal reflecting the corrected consumption / flow rate.
- Displays total and flow rate simultaneously and additional accumulated total.
- Large digit selection for flow rate or total.
- Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
- Specifications
- Features
- Downloads
| Part Number | F127 |
| Brand | Fluidwell |
| Product Type | Differential Flow Computer for liquids |
| Enclosure / Area | Safe area / Intrinsically safe |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. Different pulse signal types are allowed for input A and B. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA Output loop-powered.; 8 – 24V AC/DC.; 115 – 230V AC.; Basic: 8 - 30V DC. |
| Supply - Sensor Supply | 3.2, 8.2, 12, 24V DC. |
| Signal Outputs - Pulse Outputs | Function: One scaled pulse output according to differential or sum accumulated total (e.g. a pulse every 3.25 gallons) and one configurable pulse, negative or decreasing total output. Max. frequency: 500Hz. Adjustable pulse length from 0.001 sec. to 9.999 seconds.; Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays. |
| Signal Outputs - Analog Outputs | Function: Re-transmitting the compensated differential flow rate (consumption) - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).; Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output. |
| Hazardous Area - Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIB/IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da; IECEx: Gas: Ex ia IIC/IIB T4 Ga Dust: Ex ia IIIC T200 100 °C Da. |
| Communication | Function: All process data and settings can be read and modified through the communication link. Protocol: Modbus RTU. Interface: RS232 / RS485 2-wire or 4-wire / TTL. |
| Signal Inputs - Temperature Inputs | PT100 - 2 or 3 wire PRTD sensor.; (0)4 – 20mA. |
displays the total, accumulated total, and adjusted consumption (flow rate).
Supply line: shows the corrected flow rate and the real temperature.
Actual temperature and corrected flow rate are shown on the return line.
An analog output signal that shows the flow rate and adjusted usage.
simultaneously shows the total, the flow rate, and any additional accumulated total.
Large digit selection available for total or flow rate.
Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
Total: seven resettable digits measuring 17 mm (0.67").
Total accumulated: eleven 8mm (0.31") non-resetable digits.
Six 17mm (0.67"). temperature digits.
On the display are engineering units for temperature, flow rate, and total.
LED backlighting.
ATEX and IECEx certified as intrinsically safe. GRP, aluminum, or premium stainless steel enclosure.
EEPROM memory is used for automatic setting and running total backups.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F126-EG | Intrinsically Safe Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F126-EG | Intrinsically Safe Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C