FLUIDWELL F126-EG | Intrinsically safe - Flow Computer for gas | with temperature and pressure compensation for corrected volume | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
The F126-EG flow computer was designed to compute corrected gas volume under typical circumstances. By measuring the uncorrected volumetric flow, actual line temperature, and pressure—all of which are processed using equations kept in the flow computer—one can determine the corrected volumetric flow. One can adjust a compressibility factor to approximate the behavior of a real gas. It is possible to define the reference conditions as desired (e.g., 1.013 bar and 15°C or 60°F).
The display indicates the real line temperature and pressure in addition to the corrected flow rate, total, and accumulated total. Nm³ and other on-screen engineering units are readily configurable from a wide range of options.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Flowmeter Inputs Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. Temperature Inputs PT100 - 2 or 3 wire PRTD sensor. Pressure Inputs (0)4 " 20mA. |
Power Supply | Long life Lithium battery. 4 " 20mA Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply 3.2, 8.2, 12, 24V DC. |
computes the total, accumulated total, and adjusted flow rate.
shows the temperature and line pressure as it is.
An analog signal that is output that shows the flow rate correction.
simultaneously shows the total, the flow rate, and any additional accumulated total.
Counting in seven 8mm (0.31") increments.
Total: seven resettable digits measuring 17 mm (0.67").
Total accumulated: eleven 8mm (0.31") non-resetable digits.
Six 17mm (0.67"). temperature digits.
Six 17mm (0.67") digits of pressure.
On the display are engineering units for temperature, pressure, flow rate, and total.
LED backlighting.
intrinsic safety as defined by IECEx and ATEX.
Enclosures made of GRP, aluminum, or premium stainless steel.
EEPROM memory is used for automatic setting and running total backups.
From -40°C to +80°C (40°F to 176°F) is the ambient temperature.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT