Client Protection
Dedicated Support
Genuine Products
Dwyer CDT-2N4E-LCD | Carbon Dioxide Transmitter | 32 to 122°F (0 to 50°C), Backplate
The Dwyer CDT-2N4E-LCD is a carbon dioxide transmitter with temperature range 32 to 122°F (0 to 50°C), output Universal: 4-20 mA, 0-5 VDC or 0-10 VDC and electrical connection Backplate. Dwyer lists by integrating temperature and CO2 readings into a single transmitter, you may reduce inventory and save time., uses Automatic Baseline Correction (ABC) to correct for sensor drift and requires little maintenance. and use a CO2 sensor that is low energy, repeatable, and dependable to cut down on operating expenses. among its features.
- Accuracy: CO₂: ±40 ppm + 3% of reading (2000 PPM CO₂) Temperature: ±1°C at 25°C
- Approvals: CE
- Enclosure Rating: IP20 (wall mount)
- Humidity: Limits: 0 to 85% RH (non-condensing)
- Maximum Operating Temperature: 32 to 122°F (0 to 50°C)
- Mounting: Wall mount, North American housing
- Output: Universal: 4-20 mA, 0-5 VDC or 0-10 VDC
- POWER CONSUMPTION: Average: 2 W Peak: 3.75 W
- Specifications
- Features
- Downloads
| Accuracy | CO₂: ±40 ppm + 3% of reading (2000 PPM CO₂) Temperature: ±1°C at 25°C |
| Approvals | CE |
| Enclosure Rating | IP20 (wall mount) |
| Humidity | Limits: 0 to 85% RH (non-condensing) |
| Manufacturer | Dwyer Instruments |
| Maximum Operating Temperature | 32 to 122°F (0 to 50°C) |
| Mounting | Wall mount, North American housing |
| Output | Universal: 4-20 mA, 0-5 VDC or 0-10 VDC |
| POWER CONSUMPTION | Average: 2 W Peak: 3.75 W |
| Power | 16-35 VDC or 19-28 VAC |
| Range | CO₂: 0-2000 PPM Temperature: 32 to 122°F (0 to 50°C) |
| Response Time | 2 minutes |
| Sensor Type | Single-beam, dual-wavelength NDIR (15-year life expectancy) |
| Temperature Output | Pt1000 Ω RTD |
| Temperature Range | 32 to 122°F (0 to 50°C) |
| Display | Integral LCD |
| Relay | None |
| Electrical Connection | Backplate |
| Type | Carbon Dioxide/Temperature Transmitter |
| Part Number | CDT-2N4E-LCD |
- By integrating temperature and CO2 readings into a single transmitter, you may reduce inventory and save time.
- Uses Automatic Baseline Correction (ABC) to correct for sensor drift and requires little maintenance.
- Use a CO2 sensor that is low energy, repeatable, and dependable to cut down on operating expenses.
- Using a backplate electrical connection will simplify installation.
Related Products
Vaisala GMW90 Series | CO2, Temperature and Humidity Transmitter | CO2 + T + optional RH, Modbus RTU, 3-point CO2 calibration
Vaisala GMW90 Series | CO2, Temperature and Humidity Transmitter | CO2 + T + optional RH, Modbus RTU, 3-point CO2 calibration
Vaisala GMD110 | Duct CO2 Transmitter | ±40 ppm CO2, CARBOCAP, IP65
Vaisala GMD110 | Duct CO2 Transmitter | ±40 ppm CO2, CARBOCAP, IP65
Vaisala XMW85 Series | CO2, Humidity and Temperature Transmitter | CO2 + RH + T, ±3 %RH, Modbus RTU
Vaisala XMW85 Series | CO2, Humidity and Temperature Transmitter | CO2 + RH + T, ±3 %RH, Modbus RTU
Vaisala GMW80 Series | CO2, Humidity and Temperature Transmitter | CARBOCAP CO2, Up to 15 years stability, 8 models
Vaisala GMW80 Series | CO2, Humidity and Temperature Transmitter | CARBOCAP CO2, Up to 15 years stability, 8 models
Dwyer CMS300-FC | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300-FC | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300 | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300 | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer GSTC-N-LCD-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM