The Dwyer CDTR-2E404 is a wall-mounted carbon dioxide and relative humidity transmitter with a 0-2000 PPM CO₂ range, 0-100% RH measurement, and universal 4-20 mA, 0-5 VDC or 0-10 VDC outputs. Designed with a European wall-mount housing, this model has no temperature output and is suited to building automation and demand-controlled ventilation applications.

Genuine Dwyer Instruments stock · Free UAE-wide shipping

Part Number: CDTR-2E404

Request a quote in under a minute — call +971 6 5436933.

Product Overview

The Dwyer CDTR-2E404 combines carbon dioxide and relative humidity measurement in a compact European wall-mount enclosure, reducing the number of separate sensors required for indoor environmental monitoring.

The transmitter measures CO₂ from 0 to 2000 PPM and relative humidity from 0 to 100% RH. Although the CDTR family can include temperature measurement, the CDTR-2E404 does not provide a temperature output.

A single-beam, dual-wavelength NDIR CO₂ sensor automatically corrects the CO₂ measurement for light-source aging, helping maintain measurement performance over the sensor's operating life. The transmitter also provides digital barometric pressure adjustment and field calibration.

Dwyer's Digital Intelligence Temperature Compensation Algorithm (DITCA™) compensates for errors associated with self-heating in wall-mounted combination devices.

Universal outputs provide flexibility when connecting the transmitter to building management systems. Both CO₂ and relative humidity can be configured for 4-20 mA, 0-5 VDC or 0-10 VDC, allowing compatibility with a wide range of building controllers. Current outputs support loads up to 500 Ω, while voltage outputs require a minimum 500 Ω load.

The humidity and temperature sensors are replaceable, and a physical hardware lockout helps protect configuration settings. Because this model does not include an integral display, a service display tool is available for setup and calibration.

The CDTR-2E404 operates from 16-35 VDC or 19-28 VAC, with average power consumption of 2 W and peak consumption of 3.75 W. Its operating temperature range is 32 to 122°F (0 to 50°C), with an enclosure rating of IP20.

Key Benefits

  • Measures 0-2000 PPM CO₂ and 0-100% RH
  • European wall-mount housing
  • No temperature output on this specific configuration
  • Single-beam dual-wavelength NDIR CO₂ sensor
  • Automatic correction for CO₂ sensor light-source aging
  • Digital barometric pressure adjustment and field calibration
  • DITCA™ compensation for self-heating effects
  • Selectable 4-20 mA, 0-5 VDC or 0-10 VDC outputs
  • Replaceable humidity and temperature sensors
  • Physical hardware lockout
  • Service display tool available for setup and calibration
  • Compact IP20 wall-mount enclosure
  • Genuine Dwyer Instruments stock with free UAE-wide shipping

Who This Product Is Best For

The Dwyer CDTR-2E404 is suitable for indoor environmental monitoring and building automation applications where CO₂ and relative humidity measurement are required without a dedicated temperature output.

It is particularly useful for:

  • Demand-controlled ventilation in schools, offices and hospitals
  • Commercial building HVAC systems
  • Building management and automation systems
  • Projects requiring CO₂ and humidity monitoring from one wall-mounted device
  • LEED-focused ventilation monitoring applications
  • Installations requiring flexible analog outputs

How to Specify & Commission It

  1. Mount the European wall-mount transmitter according to the installation requirements.
  2. Connect the appropriate power supply and wire the required 4-20 mA, 0-5 VDC or 0-10 VDC outputs to the controller.
  3. Configure the barometric pressure setting for the installation and perform field calibration if required.
  4. Verify the CO₂ and relative humidity readings at the connected controller.
  5. Confirm that the selected output configuration corresponds correctly with the building management system.

Frequently Asked Questions

What does the Dwyer CDTR-2E404 measure?

The CDTR-2E404 measures CO₂ from 0-2000 PPM and relative humidity from 0-100% RH. This particular model has no temperature output.

What outputs are available?

The transmitter provides universal 4-20 mA, 0-5 VDC and 0-10 VDC outputs for CO₂ and relative humidity.

How accurate is the CDTR-2E404?

CO₂ accuracy is ±40 PPM + 3% of reading, while relative humidity accuracy is ±2%.

Does the CDTR-2E404 provide temperature output?

No. The CDTR-2E404 has no temperature output. The CDTR family includes other configurations that provide temperature measurement, but this model is intended for CO₂ and RH measurement.

Does the CDTR-2E404 have an integral display?

No. There is no integral display. A service display tool is available for setup and calibration.

Does the transmitter require recalibration?

For buildings occupied 24 hours a day, Dwyer recommends verifying calibration every 6 to 12 months, depending on the application.

What type of CO₂ sensor does it use?

It uses a single-beam, dual-wavelength NDIR sensor with automatic correction for light-source aging.

What is DITCA™?

DITCA™, or Digital Intelligence Temperature Compensation Algorithm, compensates for measurement errors associated with self-heating in wall-mounted combination devices.

What power supply does the CDTR-2E404 require?

It operates from 16-35 VDC or 19-28 VAC. Average power consumption is 2 W, with a peak of 3.75 W.

Is genuine stock available with UAE shipping?

Yes. Genuine Dwyer Instruments stock with free UAE-wide shipping is available. Call +971 6 5436933 for pricing and current availability.

Request a Quote Today

For pricing, availability or technical assistance with the Dwyer CDTR-2E404 CO₂/RH transmitter, contact General Tech Services LLC.

Call: +971 6 5436933
Website: www.generaltechshop.ae

 

Availability: low stock
Free UAE shipping available
For pricing, please contact our experts.