Product Overview

The Dwyer Series GSTC-N-FC Nitrogen Dioxide Transmitter is designed to monitor nitrogen dioxide (NO₂) concentrations in mechanical rooms, underground parking garages, loading docks, and other areas requiring diesel engine exhaust monitoring.

The GSTC-N-FC is the nitrogen dioxide version in a wall-mount configuration and communicates over RS-485 using BACnet MS/TP or Modbus® RTU protocols. This allows the transmitter to integrate with building management systems and controllers.

The transmitter features an industrial-grade, field-replaceable sensor. Field calibration can be performed using the A-449 remote LCD service display. When the sensor reaches the end of its service life, the service display indicates that replacement is required.

The GSTC-N-FC includes a factory calibration certificate. For applications that do not require factory calibration documentation, the standard GSTC-N configuration is available without the certificate.

Key Benefits

  • Designed for nitrogen dioxide (NO₂) monitoring from diesel engine exhaust
  • BACnet MS/TP or Modbus® RTU communication over 2-wire RS-485
  • Industrial-grade field-replaceable sensor
  • A-449 remote LCD service display available for setup and field calibration
  • Wall-mount configuration for garages, loading docks, and mechanical rooms
  • Supports integration with building management systems
  • Sensor status can be checked using the service display
  • Factory calibration certificate included
  • Genuine Dwyer Instruments stock with free UAE-wide shipping

Who This Product Is Best For

  • Underground parking garages requiring nitrogen dioxide monitoring
  • Loading docks with diesel vehicle exhaust
  • Mechanical rooms requiring NO₂ monitoring
  • Building management system installations using BACnet or Modbus
  • BMS integrators standardising on RS-485 gas sensing
  • Facilities requiring a wall-mounted NO₂ transmitter without a permanent local display

How to Specify & Commission It

  1. Select a suitable wall-mount location for the GSTC-N-FC and confirm that nitrogen dioxide (NO₂) is the required gas being monitored.
  2. Connect the power supply and 2-wire RS-485 communication wiring.
  3. Configure the required BACnet MS/TP or Modbus RTU communication settings, including the appropriate protocol and address.
  4. Verify communication and readings with the building management or control system.
  5. Perform field calibration using the A-449 remote LCD service display as required.
  6. Monitor the sensor status and replace the field-replaceable sensor when the service display indicates that replacement is required.

Frequently Asked Questions

What gas does the GSTC-N-FC detect?

The GSTC-N-FC is designed to detect nitrogen dioxide (NO₂), which is associated with diesel engine exhaust.

How does the GSTC-N-FC connect to a building management system?

It communicates over a 2-wire RS-485 connection using BACnet MS/TP or Modbus® RTU protocols.

Is the GSTC-N-FC wall mount or duct mount?

The GSTC-N-FC is a wall-mount model.

Does the GSTC-N-FC have a built-in LCD display?

No. The GSTC-N-FC does not have an integral LCD display. The A-449 remote LCD service display can be used for setup, calibration, and service functions.

Can the sensor be replaced in the field?

Yes. The transmitter uses an industrial-grade field-replaceable sensor.

How is the sensor calibrated?

Field calibration can be performed using the A-449 remote LCD service display.

What does the -FC suffix mean?

The -FC version is supplied with a factory calibration certificate. The standard GSTC-N configuration does not include the factory calibration certificate.

Where can the GSTC-N-FC be used?

Typical applications include underground parking garages, loading docks, mechanical rooms, and other facilities requiring nitrogen dioxide monitoring and BMS integration.

Is genuine stock available with UAE shipping?

Yes. General Tech Services LLC supplies genuine Dwyer Instruments products with free UAE-wide shipping. Call +971 6 5436933 for pricing and current availability.

Request a Quote Today

For pricing or to place an order, contact General Tech Services LLC.

Call +971 6 5436933 | www.generaltechshop.ae



Availability: low stock
Free UAE shipping available
For pricing, please contact our experts.