Skip to product information
Dwyer Instruments CDTV-2N4B4 | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 | 10K Ohm Type II temperature sensor - generaltechuae

Dwyer Instruments CDTV-2N4B4 | Wall Voc & CO2 transmitter | Universal analog outputs | 2000 ppm CO2 | 10K Ohm Type II temperature sensor

Part Number : CDTV-2N4B4

The Dwyer CDTV-2N4B4 is a wall-mounted carbon dioxide and volatile organic compound (VOC) transmitter with a 0-2000 PPM CO₂ range, VOC output correlated to 0-2000 ppm CO₂ equivalent, universal analog outputs, and a 10 kΩ Type II thermistor temperature sensor. Its North American wall-mount housing is designed for HVAC, building automation and demand-controlled ventilation applications.

Genuine Dwyer Instruments stock · Free UAE-wide shipping

Part Number: CDTV-2N4B4

Request a quote in under a minute — call +971 6 5436933.

Product Overview

The Dwyer CDTV-2N4B4 combines CO₂ and VOC measurement in one compact wall-mounted transmitter, helping building operators monitor occupancy-related carbon dioxide levels while also detecting VOC conditions that may require additional ventilation.

The transmitter measures CO₂ from 0 to 2000 PPM and provides a VOC output correlated to 0-2000 ppm CO₂ equivalent. Combining these measurements in one device can reduce the need for separate transmitters and simplify installation in HVAC and building automation systems.

The CDTV-2N4B4 uses a single-beam, dual-wavelength NDIR CO₂ sensor and a MEMS metal oxide semiconductor VOC sensor. The NDIR CO₂ sensor is designed for use in spaces occupied 24 hours a day, while the VOC measurement can help identify fumes and other air-quality conditions during periods of lower occupancy.

A 10 kΩ Type II thermistor provides temperature sensing. The transmitter also features jumper-selectable universal analog outputs. Current output can be configured as 0-20, 4-20, 0-10 or 2-10 mA, while voltage output can be configured as 0-10, 2-10, 0-5 or 1-5 VDC.

The CDTV-2N4B4 operates from 16-35 VDC or 19-28 VAC, with average power consumption of 2 W and peak consumption of 3.75 W. The North American wall-mount enclosure has an IP20 rating and operates from 32 to 122°F (0 to 50°C).

CO₂ response time is 2 minutes for a 99% step change, while VOC response time is 5 minutes. This model does not include an integral display. The CDTV-2N4B4-LCD is the corresponding configuration with an integral LCD display.

Key Benefits

  • Simultaneous CO₂ and VOC measurement from one wall-mounted device
  • 0-2000 PPM CO₂ range
  • VOC output correlated to 0-2000 ppm CO₂ equivalent
  • 10 kΩ Type II thermistor temperature sensor
  • Single-beam dual-wavelength NDIR CO₂ sensor
  • MEMS metal oxide semiconductor VOC sensor
  • Jumper-selectable universal current and voltage outputs
  • Compact North American wall-mount housing
  • Suitable for demand-controlled ventilation and building automation
  • No integral display
  • Genuine Dwyer Instruments stock with free UAE-wide shipping

Who This Product Is Best For

The Dwyer CDTV-2N4B4 is suited for HVAC engineers, facility managers and building automation professionals who need combined CO₂ and VOC monitoring from a single wall-mounted transmitter.

It is particularly useful for:

  • Demand-controlled ventilation in hospitals, schools and commercial buildings
  • Spaces occupied 24 hours a day, including waiting rooms and similar facilities
  • HVAC and building automation systems
  • Applications requiring both occupancy-related CO₂ and VOC monitoring
  • Projects where combining CO₂ and VOC sensing can reduce installation requirements
  • Systems requiring flexible analog output ranges

How to Specify & Commission It

  1. Mount the North American wall-mount transmitter according to the installation requirements.
  2. Connect the appropriate power supply and configure the output jumpers for the required current or voltage range.
  3. Connect the CO₂ and VOC outputs to the building controller.
  4. Connect the temperature output as required by the control system.
  5. Verify the readings at the controller and allow approximately 2 minutes for CO₂ and 5 minutes for VOC response when evaluating a step change.

Frequently Asked Questions

What does the CDTV-2N4B4 measure?

The CDTV-2N4B4 measures CO₂ from 0-2000 PPM and VOC with an output correlated to 0-2000 ppm CO₂ equivalent. It also includes a 10 kΩ Type II thermistor temperature sensor.

What sensors does the CDTV-2N4B4 use?

It uses a single-beam, dual-wavelength NDIR sensor for CO₂ and a MEMS metal oxide semiconductor sensor for VOC. Temperature is measured using a 10 kΩ Type II thermistor.

What outputs are available?

The current output can be jumper selected between 0-20, 4-20, 0-10 and 2-10 mA. Voltage output can be selected between 0-10, 2-10, 0-5 and 1-5 VDC.

How accurate is the CO₂ measurement?

CO₂ accuracy is ±40 PPM + 3% of reading.

How fast does the CDTV-2N4B4 respond?

CO₂ response time is 2 minutes for a 99% step change, while VOC response time is approximately 5 minutes.

Does the CDTV-2N4B4 have a display?

No. This model does not include an integral display. The CDTV-2N4B4-LCD provides the corresponding version with an integral LCD.

What is the difference between CDTV-2N4B4 and CDTV-2N4B4-LCD?

Both models provide CO₂, VOC and temperature sensing with the same general wall-mount configuration. The CDTV-2N4B4-LCD includes an integral LCD, while the CDTV-2N4B4 does not.

What is the enclosure rating?

The CDTV-2N4B4 has an IP20 enclosure rating.

What power supply does the CDTV-2N4B4 require?

It operates from 16-35 VDC or 19-28 VAC. Average power consumption is 2 W, with a peak of 3.75 W.

Is genuine stock available with UAE shipping?

Yes. Genuine Dwyer Instruments stock with free UAE-wide shipping is available. Call +971 6 5436933 for pricing and current availability.

Request a Quote Today

For pricing, availability or technical assistance with the Dwyer CDTV-2N4B4 VOC and CO₂ transmitter, contact General Tech Services LLC.

Call: +971 6 5436933
Website: www.generaltechshop.ae

 

Availability: low stock
Free UAE shipping available
For pricing, please contact our experts.