Dwyer Instruments DFC-48010-V-ALA2 | Digital flow controller | 0-10 l/min with LED display | 1/8" compression fittings | 0-5 VDC output | RS-232 digital interface | (RS-485)selectable
For precise readings and control, the Model DFC-48010-V-ALA2 DFC Digital Flow Controller combines a restrictor flow element with a straight tube sensor. Multiple industries benefit from simultaneous displays of temperature, pressure, mass flow, and volumetric flow characteristics. includes a traceable NIST certification.

Free UAE shipping available
- Specifications
- Features
- Downloads
Accuracy | +/-(0.5% of reading + 0.2% FS) |
Approvals | CE |
Connection | Process: 1/8" compression fitting for flow rates ¢°¤ 10 L/min (-005, -010) |
Display | 2 x 16 character OLED |
Leak Integrity | 1 x 10-9 sccs of helium |
Manufacturer | Dwyer Instruments |
Material | Wetted: 316 SS, 416 SS, high temperature polyamide, alumina ceramic, epoxy, silicone, glass, gold. FKM O-rings |
Maximum Operating Pressure | 120 psig (8.27 bar) |
Maximum operating temperature | 14 to 140°F (-10 to 60°C) |
Maximum Particulate Size | 20 microns |
Output | 0-5 VDC, 4-20 mA and 0-10 VDC |
Power Supply | 12-26 VDC |
Relay | Rating: Programmable solid state relay |
Repeatability | +/-0.2% FS |
Response Time | 150 ms |
Type | Digital Flow Controller |
Weight | DFC-01/50: 1.40 lbs (0.635 kg) DFC-51/56: 1.66 lbs (0.755 kg) |
- Able to perceive changes fast because of a response time of less than 20 ms.
- easy configuration using software for calibration and configuration.
- With up to ninety different user-selectable gases and gas mixtures, it works for a wide range of applications.
- Fulfill application requirements with a high degree of precision and consistency.
- Reduce downtime by using OLED or status LED indication for self-diagnostics.
Related Products

Wohler DC 410 FLOW | Pressure Differential & Flow Meter

Wohler DC 410 FLOW | Pressure Differential & Flow Meter

Dwyer Instruments GFC-2143 | Gas mass flow controller | Range 0-200 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2143 | Gas mass flow controller | Range 0-200 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2142 | Gas mass flow controller | Range 0-100 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2142 | Gas mass flow controller | Range 0-100 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 3/8" compression fitting

Dwyer Instruments GFC-2133 | Gas mass flow controller | Range 0-50 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2133 | Gas mass flow controller | Range 0-50 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2131 | Gas mass flow controller | Range 0-30 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2131 | Gas mass flow controller | Range 0-30 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2111 | Gas mass flow controller | Range 0-15 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2111 | Gas mass flow controller | Range 0-15 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2109 | Gas mass flow controller | Range 0-5 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2109 | Gas mass flow controller | Range 0-5 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2108 | Gas mass flow controller | Range 0-2 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting

Dwyer Instruments GFC-2108 | Gas mass flow controller | Range 0-2 LPM. Specified flow Range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg | 1/4" compression fitting