FLUIDWELL F112 Intrinsically safe - Flow rate Indicator / Totalizer | with linearization | Modbus, analog and pulse outputs | Ambient temperature: -40°C to +80°C (-40°F to 176°F).
The F112 is a multifunctional transmitter, totalizer, and flow rate indicator that can accurately linearize the flowmeter signal. Fifteen linearization points with their corresponding frequencies or values can be entered in addition to the average K-Factor or Span. Even for very low frequency applications, the device will interpolate between these locations, significantly improving accuracy in any flow range. Both the output signals and the presented data are impacted by this linearization.
simultaneously shows the total, the flow rate, and any additional accumulated total. From a wide assortment, on-screen engineering units are simple to configure.

Free UAE shipping available
- Specifications
- Features
- Downloads
Input | Flowmeter Inputs Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. (0)4 " 20mA. Status Inputs : Remote control: external reset for clearing total or to disable manual clearing by the keypad. |
Power Supply | Long life Lithium battery. 4 " 20mA Loop-powered. 8 " 24V AC/DC. 115 " 230V AC. Basic: 8 - 30V DC. Sensor Supply : 3.2, 8.2, 12, 24V DC. |
- The flow curve was linearized at fifteen points using interpolation.
- Pulse and analog outputs.
- simultaneously shows the flow rate, the linearized total, and the additional cumulative total.
- Large digit selection available for total or flow rate.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct engineering units on the display for the total and flow rate.
- To lock the "clear total" button or reset the total, use a remote control.
- LED backlighting.
- intrinsic safety as defined by IECEx and ATEX.
- Enclosures made of GRP, aluminum, or premium stainless steel.
- EEPROM memory is used for automatic setting and running total backups.
- From -40°C to +80°C (40°F to 176°F) is the ambient temperature.
Related Products

Nuflo MC II Flow Analyzer

Nuflo MC II Flow Analyzer

NUFLO MC-III Digital Totalizer and Transmitter

NUFLO MC-III Digital Totalizer and Transmitter

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-3/4 | Polycarbonate sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2-A711 | Polycarbonate sight flow indicator with A-711 sensor | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-801-1/2 | Polycarbonate sight flow indicator only | Range 2-20 GPM (7.6-75.5 LPM) | 1/2" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4-A711 | Polysulfone sight flow indicator with A-711 sensor | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT

Dwyer Instruments SFI-800-3/4 | Polysulfone sight flow indicator only | Range 3-35 GPM (11.4-132.5 LPM) | 3/4" female NPT