Skip to product information
Micronics UX5000 | Hazardous Area Clamp-on Ultrasonic Flow Meter | Zone 1 & 2, 50–300 mm OD - generaltechuae

Micronics UX5000 | Hazardous Area Clamp-on Ultrasonic Flow Meter | Zone 1 & 2, 50–300 mm OD

Part Number : UX5000

The Micronics UX5000 is a fixed clamp-on ultrasonic flow meter for liquid flow measurement in Zone 1 and Zone 2 hazardous areas, offered in ATEX, IECEx and UKEX-certified configurations. A separate display/control unit (DCSIU) and intrinsically safe Remote Measurement Unit (RMU) give flexibility in installation, with sensors clamped to pipes from 50 to 300 mm OD. It suits acoustically conductive liquids with under 3% particulates in chemical, petrochemical, water, oil and utility applications.

Key features

  • Cross-correlation transit-time measurement with no pipe cutting or process downtime
  • Single-channel, dual-channel and dual-path options
  • Accuracy up to 0.5% with process calibration; repeatability ±0.15%
  • Two active 4–20 mA outputs, three relay outputs and Modbus RTU over RS485
  • IP66 marine-grade powder-coated aluminium enclosures; MET (NRTL) Class I Div 1 listing
  • Graphical LCD with guided set-up; remote set-up and monitoring
Availability: in stock
For pricing, please contact our experts.