Skip to product information
Dwyer Instruments CDTR-2D4B4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & 10 kO Type 2 thermistor temperature output - generaltechuae

Dwyer Instruments CDTR-2D4B4 | Carbon Dioxide/RH/Temperature Transmitter | 2000 ppm CO2 range | Duct mount | 4 to 20 mA/0 to (5 or 10) VDC CO2 output | RH outputs & 10 kO Type 2 thermistor temperature output

Part Number : CDTR-2D4B4

The Dwyer Instruments CDTR-2D4B4 is a duct mount CO₂, relative humidity and temperature transmitter designed for indoor air quality monitoring and demand-controlled ventilation applications. It measures 0-2000 PPM CO₂ and 0-100% RH, with a 10 kΩ Type II thermistor temperature output.

The transmitter provides universal 4-20 mA, 0-5 VDC or 0-10 VDC outputs for CO₂ and RH and features a NEMA 4X (IP66) duct housing.

Genuine Dwyer Instruments stock · Free UAE-wide shipping

Part Number: CDTR-2D4B4

Request a quote in under a minute — call +971 6 5436933.

Product Overview

The Dwyer CDTR-2D4B4 combines carbon dioxide, relative humidity and temperature measurement in a single duct-mounted transmitter, helping reduce the number of individual sensors required in HVAC and building automation systems.

It provides a 0-2000 PPM CO₂ measurement range and 0-100% RH measurement range, together with a 10 kΩ Type II thermistor temperature output. This combination allows building management and ventilation systems to monitor key indoor environmental conditions through one duct-mounted device.

The transmitter uses a single-beam dual-wavelength NDIR sensor for CO₂ measurement. The sensor automatically corrects the CO₂ measurement for light-source aging in occupied and unoccupied buildings. The CDTR-2D4B4 also supports digital barometric pressure adjustment and field calibration.

Dwyer's Digital Intelligence Temperature Compensation Algorithm (DITCA™) helps eliminate measurement error associated with self-heating in combination sensing devices.

Universal analog outputs for CO₂ and RH can be selected as 4-20 mA, 0-5 VDC or 0-10 VDC, allowing integration with a wide range of building management controllers. The current output supports a maximum 500 Ω load, while voltage outputs require a minimum 500 Ω load.

The humidity and temperature sensors are replaceable, and a physical hardware lockout helps protect configuration settings. The transmitter does not include an integral display, but a service display tool is available for setup and calibration.

The CDTR-2D4B4 is housed in a NEMA 4X (IP66) duct enclosure and supports duct air velocities from 0 to 4000 FPM (20.32 m/s).

Key Benefits

  • Measures CO₂, relative humidity and temperature in one duct-mounted device
  • 0-2000 PPM CO₂ measurement range
  • 0-100% RH measurement range
  • 10 kΩ Type II thermistor temperature output
  • Single-beam dual-wavelength NDIR CO₂ sensor
  • Automatic correction for CO₂ sensor light-source aging
  • Digital barometric pressure adjustment and field calibration
  • DITCA™ temperature compensation
  • Universal 4-20 mA, 0-5 VDC and 0-10 VDC outputs
  • Replaceable humidity and temperature sensors
  • Physical hardware lockout
  • NEMA 4X (IP66) duct housing
  • Suitable for demand-controlled ventilation and building automation
  • Genuine Dwyer Instruments stock with free UAE-wide shipping

Who This Product Is Best For

The Dwyer CDTR-2D4B4 is suitable for HVAC engineers, facility managers, building automation professionals and system integrators who need CO₂, humidity and temperature measurements from a single duct-mounted transmitter.

Typical applications include demand-controlled ventilation in schools, offices, hospitals and other occupied buildings, as well as indoor air quality monitoring, building management systems and ventilation projects requiring combined CO₂, RH and temperature measurement.

It is also suitable for projects where environmental measurements are required for ventilation control and energy-efficiency monitoring.

How to Specify & Commission It

  1. Install the CDTR-2D4B4 duct mount transmitter according to the manufacturer's installation requirements.
  2. Connect the appropriate 16-35 VDC or 19-28 VAC power supply.
  3. Wire the CO₂ and RH outputs and select 4-20 mA, 0-5 VDC or 0-10 VDC as required.
  4. Connect the temperature output from the 10 kΩ Type II thermistor to the appropriate controller input.
  5. Set the required barometric pressure value.
  6. Perform field calibration if required using the service display tool.
  7. Verify CO₂, RH and temperature readings at the connected controller before commissioning.

Frequently Asked Questions

What does the Dwyer CDTR-2D4B4 measure?

The CDTR-2D4B4 measures CO₂ from 0-2000 PPM and relative humidity from 0-100% RH, with a 10 kΩ Type II thermistor temperature output.

What type of temperature sensor does the CDTR-2D4B4 use?

It uses a 10 kΩ Type II thermistor for temperature measurement.

What outputs are available?

The transmitter provides universal 4-20 mA, 0-5 VDC or 0-10 VDC outputs for CO₂ and RH.

How accurate is the CDTR-2D4B4?

CO₂ accuracy is ±40 ppm + 3% of reading, while relative humidity accuracy is ±2%.

What type of CO₂ sensor does it use?

The transmitter uses a single-beam, dual-wavelength NDIR sensor with automatic correction for light-source aging.

Does the CDTR-2D4B4 have a display?

No. The transmitter has no integral display. A service display tool is available for setup and calibration.

Does the CDTR-2D4B4 require recalibration?

For buildings occupied 24 hours a day, Dwyer recommends verifying calibration every 6 to 12 months, depending on the application.

What is the enclosure rating?

The duct housing is rated NEMA 4X (IP66).

What power supply does it require?

The transmitter operates from 16-35 VDC or 19-28 VAC. Average power consumption is 2 W, with peak consumption of 3.75 W.

Is genuine stock available with UAE shipping?

Yes. Genuine Dwyer Instruments stock is available through General Tech Services LLC with free UAE-wide shipping. Call +971 6 5436933 for pricing and current availability.

Request a Quote Today

For pricing, availability or technical assistance for the Dwyer CDTR-2D4B4 CO₂/RH/temperature transmitter, contact General Tech Services LLC.

Call: +971 6 5436933
Website: www.generaltechshop.ae

 

Availability: low stock
Free UAE shipping available
For pricing, please contact our experts.