Dwyer Instruments CDWP-05W-C1 | Industrial CO2 Transmitter | 0-5000 PPM range | Wall mount | With 1-6mm cable gland
To help save energy, the Series CDWP, Model CDWP-05W-C1 Carbon Dioxide Transmitter precisely measures the CO2 content in indoor and industrial settings. The tough IP54 aluminum housing used by the CDWP has an external gray paint coat and has been tested to survive a 168-hour salt spray corrosion test. Because of its ruggedized housing, which guards against liquid splashes and flying dust and debris, the Series CDWP is a fantastic choice for confined feeding operations and animal husbandry applications.

Free UAE shipping available
- Specifications
- Features
- Downloads
Accuracy | CO2: +/-40 PPM + 3% of reading (2000 PPM); +/-50 PPM + 5% of reading (5000 PPM); +/-50 PPM + 10% of reading (10000 PPM) |
Approvals | CE |
Enclosure Rating | IP54 |
Humidity | Limits: 10 to 95% RH (non-condensing, 2000 and 5000 PPM); 0 to 85% RH (non-condensing, 10000 PPM) |
Maximum operating temperature | 32 to 122°F (0 to 50°C) |
Mounting | Orientation: Vertically, with electrical connections pointing downward |
Non Linearity | 16 PPM (2000 and 5000 PPM); N/A (10000 PPM) |
Output | Current: 4-20 mA (max. 500 ¢ž¦) Voltage: 0-5 VDC or 0-10 VDC (min. 500 ¢ž¦) |
POWER CONSUMPTION | Average: 2 w Peak: 3.75 w |
Power | 16-35 VDC or 19-28 VAC |
PRESSURE | Dependence: 0.13% of reading per mm of Hg (2000 and 5000 PPM); N/A (10000 PPM) |
Range | CO2: 0 to 2000, 0 to 5000, or 0 to 10000 PPM (depending on model) |
Response Time | 300 s (t63) (2000 and 5000 PPM); 2 min for 90% step change (10000 PPM) |
Sensor Type | NDIR |
Temperature | Dependence: +/-8 PPM/°C at 1100 PPM (2000 and 5000 PPM); N/A (10000 PPM) |
Weight | 26.24 oz (744 g) |
- There are no issues with the tough aluminum housing's durability.
- The IP54 housing is resistant to corrosion and water infiltration, and it can sustain 168 hours of salt spray testing.
- Lower operating costs by employing a CO2 sensor that is low energy, consistent, and dependable.
Related Products

Dwyer Instruments CMS300-FC | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω) | Includes factory calibration certificate

Dwyer Instruments CMS300-FC | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω) | Includes factory calibration certificate

Dwyer Instruments CMS300 | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω)

Dwyer Instruments CMS300 | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω)

Dwyer Instruments GSTC-N-LCD-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | LCD display | Includes factory calibration certificate

Dwyer Instruments GSTC-N-LCD-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | LCD display | Includes factory calibration certificate

Dwyer Instruments GSTC-N-LCD | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display

Dwyer Instruments GSTC-N-LCD | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display

Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-D-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-D-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-D | Nitrogen Dioxide Duct Mount Transmitter with BACnet & Modbus Communication

Dwyer Instruments GSTC-N-D | Nitrogen Dioxide Duct Mount Transmitter with BACnet & Modbus Communication

Dwyer Instruments GSTC-N | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication

Dwyer Instruments GSTC-N | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication