Mitutoyo 963-210-20 | HR-110MR Rockwell Hardness Testing Machines
• The newly designed frame provides maximum clearance for positioning the workpiece. A table or bench is all that is needed for mounting these testing machines.
• Simple to operate. With the analogue type, HR-110MR, the gauge presetting operation has been eliminated by the adoption of an automatic presetting dial gauge.
• The HR-430MS uses an automatic steering wheel brake and loading sequence to enable simple test handling.
• HR-110MR does not require a power source, and is considered to be environmentally friendly.
• The digital types HR-320MS and HR-430MS provide Digimatic output for direct data transfer to the DP-1VA LOGGER Digimatic Mini-Processor, and the USB-ITN-E input tool can be used to connect to a PC for data transfer and processing.
• Brinell hardness tests can be performed by using the following optional accessories: a Brinell indenter, a weight set and a measurement microscope.
- Specifications
- Features
- Downloads
Dimensions | Approx. 296 x 512 x 780 mm |
Display | Analogue |
Mass (main unit) | Approx. 49 kg |
Minimum reading | 0.5HR graduation |
Model Number | HR-110MR |
Power Supply | No power required |
Preload force (handling support) | Automatic pre-setting dial gauge |
SKU | 963-210-20 |
Standard | JIS B 7726 |
Test force duration | Manual |
Total test force control | Manual |
Total test force setting | Weight change |
Type of hardness test | Rockwell |
• The newly designed frame provides maximum clearance for positioning the workpiece. A table or bench is all that is needed for mounting these testing machines.
• Simple to operate. With the analogue type, HR-110MR, the gauge presetting operation has been eliminated by the adoption of an automatic presetting dial gauge.
• The HR-430MS uses an automatic steering wheel brake and loading sequence to enable simple test handling.
• HR-110MR does not require a power source, and is considered to be environmentally friendly.
• The digital types HR-320MS and HR-430MS provide Digimatic output for direct data transfer to the DP-1VA LOGGER Digimatic Mini-Processor, and the USB-ITN-E input tool can be used to connect to a PC for data transfer and processing.
• Brinell hardness tests can be performed by using the following optional accessories: a Brinell indenter, a weight set and a measurement microscope.
Related Products

Mitutoyo 810-522-23 | Rockwell Hardness Testing Machines | HR-620A mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 350x681x935 mm

Mitutoyo 810-522-23 | Rockwell Hardness Testing Machines | HR-620A mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 350x681x935 mm

Mitutoyo 810-512-23 | Rockwell Hardness Testing Machines | HR-610A mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 350x681x935 mm

Mitutoyo 810-512-23 | Rockwell Hardness Testing Machines | HR-610A mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 350x681x935 mm

Mitutoyo 810-527-21 | Rockwell Hardness Testing Machines | HR-620B main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 428x837x935 mm

Mitutoyo 810-527-21 | Rockwell Hardness Testing Machines | HR-620B main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 428x837x935 mm

Mitutoyo 810-333-33 | Rockwell Hardness Testing Machines | HR-530L mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 250x667x766 mm

Mitutoyo 810-333-33 | Rockwell Hardness Testing Machines | HR-530L mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 250x667x766 mm

Mitutoyo 810-233-33 | Rockwell Hardness Testing Machines | HR-530 mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 250x667x621 mm

Mitutoyo 810-233-33 | Rockwell Hardness Testing Machines | HR-530 mm/inch main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz or lower | External Dimensions 250x667x621 mm

Mitutoyo 810-193-31 | Rockwell Hardness Testing Machines | HR-430MR main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz | External Dimensions 235x512x782 mm

Mitutoyo 810-193-31 | Rockwell Hardness Testing Machines | HR-430MR main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz | External Dimensions 235x512x782 mm

Mitutoyo 810-192-31 | Rockwell Hardness Testing Machines | HR-320MS main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz | External Dimensions 235x512x781 mm

Mitutoyo 810-192-31 | Rockwell Hardness Testing Machines | HR-320MS main unit ISO-JIS-ASTM | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz | External Dimensions 235x512x781 mm

Mitutoyo 810-191-21 | Rockwell Hardness Testing Machines | HR-210MR main unit | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz | External Dimensions 235x512x780 mm

Mitutoyo 810-191-21 | Rockwell Hardness Testing Machines | HR-210MR main unit | Operation Temperature 5 to 40°C | Vibration Frequency 5Hz | External Dimensions 235x512x780 mm